  1. Article ; Online: A prototype Multi-X-ray-source array (MXA) for digital breast tomosynthesis.

    Becker, Amy E / Hernandez, Andrew M / Boone, John M / Schwoebel, Paul R

    Physics in medicine and biology

    2020  Volume 65, Issue 23, Page(s) 235033

    Abstract: The design and testing of a prototype Multi-X-ray-source Array (MXA) for digital breast tomosynthesis is reported. The MXA is comprised of an array of tungsten filament cathodes with focus cup grid-controlled modulation and a common rotating anode housed ...

    Abstract The design and testing of a prototype Multi-X-ray-source Array (MXA) for digital breast tomosynthesis is reported. The MXA is comprised of an array of tungsten filament cathodes with focus cup grid-controlled modulation and a common rotating anode housed in a single vacuum envelope. Prototypes consisting of arrays of three-source elements and eleven-source-elements were fabricated and evaluated. The prototype sources demonstrated focal spot sizes of 0.3 mm at 45 kV with 50 mA. Measured x-ray spectra were consistent with the molybdenum anode employed, and the tube output (air kerma) was between 0.6 mGy/100 mAs at 20 kV and 17 mGy/100 mAs at 45 kV with a distance of 100 cm. HVL measurements ranged from 0.5 mm Al at 30 kV to 0.8 mm Al at 45 kV, and x-ray pulse widths were varied from 20 ms to 110 ms at operating frequencies ultimately to be limited by source turn-on/off times of ∼1 ms. Initial results of reconstructed tomographic data are presented.
    MeSH term(s) Breast Neoplasms/diagnostic imaging ; Female ; Humans ; Mammography/instrumentation ; Mammography/methods ; Phantoms, Imaging ; Tomography, X-Ray Computed/instrumentation ; Tomography, X-Ray Computed/methods
    Language English
    Publishing date 2020-12-18
    Publishing country England
    Document type Journal Article ; Research Support, N.I.H., Extramural ; Research Support, U.S. Gov't, Non-P.H.S.
    ZDB-ID 208857-5
    ISSN 1361-6560 ; 0031-9155
    ISSN (online) 1361-6560
    ISSN 0031-9155
    DOI 10.1088/1361-6560/abc305
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article ; Online: Cone beam CT multisource configurations: evaluating image quality, scatter, and dose using phantom imaging and Monte Carlo simulations.

    Becker, Amy E / Hernandez, Andrew M / Schwoebel, Paul R / Boone, John M

    Physics in medicine and biology

    2020  Volume 65, Issue 23, Page(s) 235032

    Abstract: The purpose of this study was to compare various multisource configurations applied to cone beam CT (CBCT) using phantom imaging and Monte Carlo simulations. Image quality, scatter, and dose were evaluated in both overlapping (large cone angle) and ... ...

    Abstract The purpose of this study was to compare various multisource configurations applied to cone beam CT (CBCT) using phantom imaging and Monte Carlo simulations. Image quality, scatter, and dose were evaluated in both overlapping (large cone angle) and collimated (small cone angle) configurations for CBCT. Four x-ray tube configurations were considered: traditional one source, three source overlapping, six source overlapping, and six source collimated. Image quality was evaluated on a prototype breast CT system using the following five phantoms: a Defrise phantom, a previously reported CBCT QA phantom (Corgi), a polyethylene cylinder, and two anthropomorphic phantoms (hand and knee). Scatter contamination and radiation dose were evaluated using Monte Carlo simulations of a voxelized polyethylene cylinder. The modulation of the Defrise phantom disks on average was 2.7X greater for the six source collimated configuration than the six source overlapping configuration. The data lost from cone beam artifact (spatial domain) and the null cone (frequency domain) in the overlapping configuration were completely recovered using the collimated configuration. The maximum scatter-to-primary ratio (SPR) for the overlapping configuration was 0.81 and the maximum SPR for the collimated configuration was 0.26. The average dose and maximum dose was 4X less in the collimated six source configuration when compared with the overlapping configurations. The maximum dose for the overlapping configurations (one, three & six) remained constant, but the average dose for the multisource (three & six source) overlapping configurations increased 25% when compared to the one source configuration. Use of a collimated multisource x-ray tube configuration was shown to provide significant improvements in image quality throughout the cone-beam geometry field-of-view, reduction in scatter contamination, and more efficient use of dose in comparison to both the traditional CBCT geometry with a single source and the overlapping multisource configurations.
    MeSH term(s) Artifacts ; Cone-Beam Computed Tomography/methods ; Humans ; Monte Carlo Method ; Phantoms, Imaging ; Quality Control ; Radiation Dosage ; Scattering, Radiation ; Tomography, X-Ray Computed/methods
    Language English
    Publishing date 2020-12-18
    Publishing country England
    Document type Evaluation Study ; Journal Article ; Research Support, N.I.H., Extramural ; Research Support, U.S. Gov't, Non-P.H.S.