  1. Article ; Online: Experimental Validation of a Real-Time Adaptive 4D-Optimized Particle Radiotherapy Approach to Treat Irregularly Moving Tumors.

    Steinsberger, Timo / Donetti, Marco / Lis, Michelle / Volz, Lennart / Wolf, Moritz / Durante, Marco / Graeff, Christian

    International journal of radiation oncology, biology, physics

    2022  Volume 115, Issue 5, Page(s) 1257–1268

    Abstract: Purpose: Treatment of locally advanced lung cancer is limited by toxicity and insufficient local control. Particle therapy could enable more conformal treatment than intensity modulated photon therapy but is challenged by irregular tumor motion, ... ...

    Abstract Purpose: Treatment of locally advanced lung cancer is limited by toxicity and insufficient local control. Particle therapy could enable more conformal treatment than intensity modulated photon therapy but is challenged by irregular tumor motion, associated range changes, and tumor deformations. We propose a new strategy for robust, online adaptive particle therapy, synergizing 4-dimensional optimization with real-time adaptive beam tracking. The strategy was tested and the required motion monitoring precision was determined.
    Methods and materials: In multiphase 4-dimensional dose delivery (MP4D), a dedicated quasistatic treatment plan is delivered to each motion phase of periodic 4-dimensional computed tomography (4DCT). In the new extension, "MP4D with residual tracking" (MP4DRT), lateral beam tracking compensates for the displacement of the tumor center-of-mass relative to the current phase in the planning 4DCT. We implemented this method in the dose delivery system of a clinical carbon facility and tested it experimentally for a lung cancer plan based on a periodic subset of a virtual lung 4DCT (planned motion amplitude 20 mm). Treatments were delivered in a quality assurance-like setting to a moving ionization chamber array. We considered variable motion amplitudes and baseline drifts. The required motion monitoring precision was evaluated by adding noise to the motion signal. Log-file-based dose reconstructions were performed in silico on the entire 4DCT phantom data set capable of simulating nonperiodic motion. MP4DRT was compared with MP4D, rescanned beam tracking, and internal target volume plans. Treatment quality was assessed in terms of target coverage (D95), dose homogeneity (D5-D95), conformity number, and dose to heart and lung.
    Results: For all considered motion scenarios and metrics, MP4DRT produced the most favorable metrics among the tested motion mitigation strategies and delivered high-quality treatments. The conformity was similar to static treatments. The motion monitoring precision required for D95 >95% was 1.9 mm.
    Conclusions: With clinically feasible motion monitoring, MP4DRT can deliver highly conformal dose distributions to irregularly moving targets.
    MeSH term(s) Humans ; Radiotherapy Dosage ; Radiotherapy Planning, Computer-Assisted/methods ; Lung Neoplasms/diagnostic imaging ; Lung Neoplasms/radiotherapy ; Lung ; Tomography, X-Ray Computed ; Four-Dimensional Computed Tomography/methods
    Language English
    Publishing date 2022-12-01
    Publishing country United States
    Document type Journal Article
    ZDB-ID 197614-x
    ISSN 1879-355X ; 0360-3016
    ISSN (online) 1879-355X
    ISSN 0360-3016
    DOI 10.1016/j.ijrobp.2022.11.034
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Book ; Online ; Thesis: Development and experimental validation of adaptive conformal particle therapy

    Steinsberger, Timo Pascal [Verfasser] / Durante, Marco [Akademischer Betreuer] / Riboldi, Marco [Akademischer Betreuer]

    2022  

    Author's details Timo Pascal Steinsberger ; Marco Durante, Marco Riboldi
    Keywords Medizin, Gesundheit ; Medicine, Health
    Subject code sg610
    Language English
    Publisher Universitäts- und Landesbibliothek
    Publishing place Darmstadt
    Document type Book ; Online ; Thesis
    Database Digital theses on the web

    More links

    Kategorien

  3. Article: Dosimetric Validation of a System to Treat Moving Tumors Using Scanned Ion Beams That Are Synchronized With Anatomical Motion.

    Lis, Michelle / Newhauser, Wayne / Donetti, Marco / Wolf, Moritz / Steinsberger, Timo / Paz, Athena / Graeff, Christian

    Frontiers in oncology

    2021  Volume 11, Page(s) 712126

    Abstract: Purpose: The purpose of this study was to validate the dosimetric performance of scanned ion beam deliveries with motion-synchronization to heterogenous targets.: Methods: A 4D library of treatment plans, comprised of up to 10 3D sub-plans, was ... ...

    Abstract Purpose: The purpose of this study was to validate the dosimetric performance of scanned ion beam deliveries with motion-synchronization to heterogenous targets.
    Methods: A 4D library of treatment plans, comprised of up to 10 3D sub-plans, was created with robust and conventional 4D optimization methods. Each sub-plan corresponded to one phase of periodic target motion. The plan libraries were delivered to a test phantom, comprising plastic slabs, dosimeters, and heterogenous phantoms. This phantom emulated range changes that occur when treating moving tumors. Similar treatment plans, but without motion synchronization, were also delivered to a test phantom with a stationary target and to a moving target; these were used to assess how the target motion degrades the quality of dose distributions and the extent to which motion synchronization can improve dosimetric quality. The accuracy of calculated dose distributions was verified by comparison with corresponding measurements. Comparisons utilized the gamma index analysis method. Plan quality was assessed based on conformity, dose coverage, overdose, and homogeneity values, each extracted from calculated dose distributions.
    Results: High pass rates for the gamma index analysis confirmed that the methods used to calculate and reconstruct dose distributions were sufficiently accurate for the purposes of this study. Calculated and reconstructed dose distributions revealed that the motion-synchronized and static deliveries exhibited similar quality in terms of dose coverage, overdose, and homogeneity for all deliveries considered. Motion-synchronization substantially improved conformity in deliveries with moving targets. Importantly, measurements at multiple locations within the target also confirmed that the motion-synchronized delivery system satisfactorily compensated for changes in beam range caused by the phantom motion. Specifically, the overall planning and delivery approach achieved the desired dose distribution by avoiding range undershoots and overshoots caused by tumor motion.
    Conclusions: We validated a dose delivery system that synchronizes the movement of the ion beam to that of a moving target in a test phantom. Measured and calculated dose distributions revealed that this system satisfactorily compensated for target motion in the presence of beam range changes due to target motion. The implication of this finding is that the prototype system is suitable for additional preclinical research studies, such as irregular anatomic motion.
    Language English
    Publishing date 2021-09-08
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2649216-7
    ISSN 2234-943X
    ISSN 2234-943X
    DOI 10.3389/fonc.2021.712126
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  4. Article ; Online: Preliminary tests of dosimetric quality and projected therapeutic outcomes of multi-phase 4D radiotherapy with proton and carbon ion beams.

    Lis, Michelle / Newhauser, Wayne / Donetti, Marco / Wolf, Moritz / Steinsberger, Timo / Paz, Athena / Graeff, Christian

    Physics in medicine and biology

    2021  Volume 66, Issue 23

    Abstract: ... ...

    Abstract Objective
    MeSH term(s) Carbon ; Carcinoma, Non-Small-Cell Lung/pathology ; Four-Dimensional Computed Tomography/methods ; Humans ; Lung Neoplasms/diagnostic imaging ; Lung Neoplasms/radiotherapy ; Protons ; Radiotherapy Dosage ; Radiotherapy Planning, Computer-Assisted/methods ; Radiotherapy, Intensity-Modulated ; Treatment Outcome
    Chemical Substances Protons ; Carbon (7440-44-0)
    Language English
    Publishing date 2021-11-23
    Publishing country England
    Document type Journal Article ; Research Support, Non-U.S. Gov't
    ZDB-ID 208857-5
    ISSN 1361-6560 ; 0031-9155
    ISSN (online) 1361-6560
    ISSN 0031-9155
    DOI 10.1088/1361-6560/ac36e7
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  5. Article: A Modular System for Treating Moving Anatomical Targets With Scanned Ion Beams at Multiple Facilities: Pre-Clinical Testing for Quality and Safety of Beam Delivery.

    Lis, Michelle / Newhauser, Wayne / Donetti, Marco / Wolf, Moritz / Steinsberger, Timo / Paz, Athena / Durante, Marco / Graeff, Christian

    Frontiers in oncology

    2021  Volume 11, Page(s) 620388

    Abstract: Background: Quality management and safety are integral to modern radiotherapy. New radiotherapy technologies require new consensus guidelines on quality and safety. Established analysis strategies, such as the failure modes and effects analysis (FMEA) ... ...

    Abstract Background: Quality management and safety are integral to modern radiotherapy. New radiotherapy technologies require new consensus guidelines on quality and safety. Established analysis strategies, such as the failure modes and effects analysis (FMEA) and incident learning systems have been developed as tools to assess the safety of several types of radiation therapies. An extensive literature documents the widespread application of risk analysis methods to photon radiation therapy. Relatively little attention has been paid to performing risk analyses of nascent radiation therapy systems to treat moving tumors with scanned heavy ion beams. The purpose of this study was to apply a comprehensive safety analysis strategy to a motion-synchronized dose delivery system (M-DDS) for ion therapy.
    Methods: We applied a risk analysis method to new treatment planning and treatment delivery processes with scanned heavy ion beams. The processes utilize a prototype, modular dose delivery system, currently undergoing preclinical testing, that provides new capabilities for treating moving anatomy. Each step in the treatment process was listed in a process map, potential errors for each step were identified and scored using the risk probability number in an FMEA, and the possible causes of each error were described in a fault tree analysis. Solutions were identified to mitigate the risk of these errors, including permanent corrective actions, periodic quality assurance (QA) tests, and patient specific QA (PSQA) tests. Each solution was tested experimentally.
    Results: The analysis revealed 58 potential errors that could compromise beam delivery quality or safety. Each of the 14 binary (pass-or-fail) tests passed. Each of the nine QA and four PSQA tests were within anticipated clinical specifications. The modular M-DDS was modified accordingly, and was found to function at two centers.
    Conclusion: We have applied a comprehensive risk analysis strategy to the M-DDS and shown that it is a clinically viable motion mitigation strategy. The described strategy can be utilized at any ion therapy center that operates with the modular M-DDS. The approach can also be adapted for use at other facilities and can be combined with existing safety analysis systems.
    Language English
    Publishing date 2021-03-19
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2649216-7
    ISSN 2234-943X
    ISSN 2234-943X
    DOI 10.3389/fonc.2021.620388
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  6. Article ; Online: Extension of RBE-weighted 4D particle dose calculation for non-periodic motion.

    Steinsberger, Timo / Alliger, Christian / Donetti, Marco / Krämer, Michael / Lis, Michelle / Paz, Athena / Wolf, Moritz / Graeff, Christian

    Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)

    2021  Volume 91, Page(s) 62–72

    Abstract: Purpose: Highly conformal scanned Carbon Ion Radiotherapy (CIRT) might permit dose escalation and improved local control in advanced stage thoracic tumors, but is challenged by target motion. Dose calculation algorithms typically assume a periodically ... ...

    Abstract Purpose: Highly conformal scanned Carbon Ion Radiotherapy (CIRT) might permit dose escalation and improved local control in advanced stage thoracic tumors, but is challenged by target motion. Dose calculation algorithms typically assume a periodically repeating, regular motion. To assess the effect of realistic, irregular motion, new algorithms of validated accuracy are needed.
    Methods: We extended an in-house treatment planning system to calculate RBE-weighted dose distributions in CIRT on non-periodic CT image sequences. Dosimetric accuracy was validated experimentally on a moving, time-resolved ionization chamber array. Log-file based dose reconstructions were compared by gamma analysis and correlation to measurements at every intermediate detector frame during delivery. The impact of irregular motion on treatment quality was simulated on a virtual 4DCT thorax phantom. Periodic motion was compared to motion with varying amplitude and period ± baseline drift. Rescanning as a mitigation strategy was assessed on all scenarios.
    Results: In experimental validation, average gamma pass rates were 99.89+-0.30% for 3%/3 mm and 88.2+-2.2% for 2%/2 mm criteria. Average correlation for integral dose distributions was 0.990±0.002. Median correlation for single 200 ms frames was 0.947±0.006. In the simulations, irregular motion deteriorated V95 target coverage to 81.2%, 76.6% and 79.0% for regular, irregular motion and irregular motion with base-line drift, respectively. Rescanning restored V95 to >98% for both scenarios without baseline drift, but not with additional baseline drift at 83.7%.
    Conclusions: The validated algorithm permits to study the effects of irregular motion and to develop and adapt appropriate motion mitigation techniques.
    MeSH term(s) Algorithms ; Four-Dimensional Computed Tomography ; Heavy Ion Radiotherapy ; Motion ; Phantoms, Imaging ; Radiometry ; Radiotherapy Dosage ; Radiotherapy Planning, Computer-Assisted
    Language English
    Publishing date 2021-10-26
    Publishing country Italy
    Document type Journal Article
    ZDB-ID 1122650-x
    ISSN 1724-191X ; 1120-1797
    ISSN (online) 1724-191X
    ISSN 1120-1797
    DOI 10.1016/j.ejmp.2021.10.009
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  7. Article ; Online: A modular dose delivery system for treating moving targets with scanned ion beams: Performance and safety characteristics, and preliminary tests.

    Lis, Michelle / Donetti, Marco / Newhauser, Wayne / Durante, Marco / Dey, Joyoni / Weber, Ulrich / Wolf, Moritz / Steinsberger, Timo / Graeff, Christian

    Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)

    2020  Volume 76, Page(s) 307–316

    Abstract: Purpose: The purpose of this study was to develop a modular dose-delivery system (DDS) for scanned-ion radiotherapy that mitigates against organ motion artifacts by synchronizing the motion of the beam with that of the moving anatomy.: Methods: We ... ...

    Abstract Purpose: The purpose of this study was to develop a modular dose-delivery system (DDS) for scanned-ion radiotherapy that mitigates against organ motion artifacts by synchronizing the motion of the beam with that of the moving anatomy.
    Methods: We integrated a new motion synchronization system and an existing DDS into two centers. The modular approach to integration utilized an adaptive layer of software and hardware interfaces. The method of synchronization comprised three major tasks, namely, the creation of 3D treatment plans (each representing one phase of respiratory motion and together comprising a 4D plan), monitoring anatomic motion during treatment, and synchronization of the beam to anatomic motion. The synchronization was accomplished in real time by repeatedly selecting and delivering a 3D plan, i.e., the one that most closely corresponded to the current anatomic state, until all plans were delivered. The performance characteristics of the motion mitigation system were tested by delivering 4D treatment plans to a moving phantom and comparing planned and measured dose distributions. Dosimetric performance was considered acceptable when the gamma-index pass rate was >90%, homogeneity-index value was >95%, and conformity-index value was >60%. Selected safety characteristics were tested by introducing errors during treatment and testing DDS response.
    Results: Acceptable dosimetric performance and safety characteristics were observed for all treatment plans.
    Conclusions: We demonstrated, for the first time, that a modular prototype system, synchronizing scanned ion beams with moving targets can deliver conformal, motion-compensated dose distributions. The prototype system was implemented and characterized at GSI and CNAO.
    MeSH term(s) Motion ; Phantoms, Imaging ; Radiometry ; Radiotherapy Dosage ; Radiotherapy Planning, Computer-Assisted
    Language English
    Publishing date 2020-07-30
    Publishing country Italy
    Document type Journal Article
    ZDB-ID 1122650-x
    ISSN 1724-191X ; 1120-1797
    ISSN (online) 1724-191X
    ISSN 1120-1797
    DOI 10.1016/j.ejmp.2020.07.029
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  8. Article: Radioactive Beams for Image-Guided Particle Therapy: The BARB Experiment at GSI.

    Boscolo, Daria / Kostyleva, Daria / Safari, Mohammad Javad / Anagnostatou, Vasiliki / Äystö, Juha / Bagchi, Soumya / Binder, Tim / Dedes, Georgios / Dendooven, Peter / Dickel, Timo / Drozd, Vasyl / Franczack, Bernhard / Geissel, Hans / Gianoli, Chiara / Graeff, Christian / Grahn, Tuomas / Greiner, Florian / Haettner, Emma / Haghani, Roghieh /
    Harakeh, Muhsin N / Horst, Felix / Hornung, Christine / Hucka, Jan-Paul / Kalantar-Nayestanaki, Nasser / Kazantseva, Erika / Kindler, Birgit / Knöbel, Ronja / Kuzminchuk-Feuerstein, Natalia / Lommel, Bettina / Mukha, Ivan / Nociforo, Chiara / Ishikawa, Shunki / Lovatti, Giulio / Nitta, Munetaka / Ozoemelam, Ikechi / Pietri, Stephane / Plaß, Wolfgang R / Prochazka, Andrej / Purushothaman, Sivaji / Reidel, Claire-Anne / Roesch, Heidi / Schirru, Fabio / Schuy, Christoph / Sokol, Olga / Steinsberger, Timo / Tanaka, Yoshiki K / Tanihata, Isao / Thirolf, Peter / Tinganelli, Walter / Voss, Bernd / Weber, Uli / Weick, Helmut / Winfield, John S / Winkler, Martin / Zhao, Jianwei / Scheidenberger, Christoph / Parodi, Katia / Durante, Marco

    Frontiers in oncology

    2021  Volume 11, Page(s) 737050

    Abstract: Several techniques are under development for image-guidance in particle therapy. Positron ( ... ...

    Abstract Several techniques are under development for image-guidance in particle therapy. Positron (β
    Language English
    Publishing date 2021-08-19
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2649216-7
    ISSN 2234-943X
    ISSN 2234-943X
    DOI 10.3389/fonc.2021.737050
    Database MEDical Literature Analysis and Retrieval System OnLINE