LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 4 of total 4

Search options

  1. Article ; Online: Endotracheal intubation with barrier protection.

    Jazuli, Farah / Bilic, Monika / Hanel, Erich / Ha, Michael / Hassall, Kelly / Trotter, Brendon Gordon

    Emergency medicine journal : EMJ

    2020  Volume 37, Issue 7, Page(s) 398–399

    Abstract: Given the high risk of healthcare worker (HCW) infection with COVID-19 during aerosol-generating medical procedures, the use of a box barrier during intubation for protection of HCWs has been examined. Previous simulation work has demonstrated its ... ...

    Abstract Given the high risk of healthcare worker (HCW) infection with COVID-19 during aerosol-generating medical procedures, the use of a box barrier during intubation for protection of HCWs has been examined. Previous simulation work has demonstrated its efficacy in protecting HCWs from cough-expelled droplets. Our objective was to assess its ability to protect HCWs against aerosols generated during aerosol-generating medical procedures. We used a battery-powered vapouriser to assess movement of vapour with: (1) no barrier; (2) a box barrier; and (3) a box barrier and a plastic sheet covering the box and patient's body. We visualised the trajectory of vapour and saw that the vapour remained within the barrier space when the box barrier and plastic sheet were used. This is in contrast to the box barrier alone, where vapour diffused towards the feet of the patient and throughout the room, and to no barrier where the vapour immediately diffused to the laryngoscopist. This demonstrates that the box with the plastic sheet has the potential to limit the spread of aerosols towards the laryngoscopist, and thus may play a role in protecting HCWs during aerosol-generating medical procedures. This is of particular importance in the care of patients with suspected COVID-19.
    MeSH term(s) Aerosols ; Betacoronavirus ; COVID-19 ; Coronavirus Infections/prevention & control ; Coronavirus Infections/therapy ; Humans ; Infectious Disease Transmission, Patient-to-Professional/prevention & control ; Intubation, Intratracheal/methods ; Pandemics/prevention & control ; Pneumonia, Viral/prevention & control ; Pneumonia, Viral/therapy ; Protective Devices ; SARS-CoV-2
    Chemical Substances Aerosols
    Keywords covid19
    Language English
    Publishing date 2020-06-01
    Publishing country England
    Document type Journal Article
    ZDB-ID 2040124-3
    ISSN 1472-0213 ; 1472-0205
    ISSN (online) 1472-0213
    ISSN 1472-0205
    DOI 10.1136/emermed-2020-209785
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article: Endotracheal intubation with barrier protection

    Jazuli, Farah / Bilic, Monika / Hanel, Erich / Ha, Michael / Hassall, Kelly / Trotter, Brendon Gordon

    Emerg Med J

    Abstract: Given the high risk of healthcare worker (HCW) infection with COVID-19 during aerosol-generating medical procedures, the use of a box barrier during intubation for protection of HCWs has been examined. Previous simulation work has demonstrated its ... ...

    Abstract Given the high risk of healthcare worker (HCW) infection with COVID-19 during aerosol-generating medical procedures, the use of a box barrier during intubation for protection of HCWs has been examined. Previous simulation work has demonstrated its efficacy in protecting HCWs from cough-expelled droplets. Our objective was to assess its ability to protect HCWs against aerosols generated during aerosol-generating medical procedures. We used a battery-powered vapouriser to assess movement of vapour with: (1) no barrier; (2) a box barrier; and (3) a box barrier and a plastic sheet covering the box and patient's body. We visualised the trajectory of vapour and saw that the vapour remained within the barrier space when the box barrier and plastic sheet were used. This is in contrast to the box barrier alone, where vapour diffused towards the feet of the patient and throughout the room, and to no barrier where the vapour immediately diffused to the laryngoscopist. This demonstrates that the box with the plastic sheet has the potential to limit the spread of aerosols towards the laryngoscopist, and thus may play a role in protecting HCWs during aerosol-generating medical procedures. This is of particular importance in the care of patients with suspected COVID-19.
    Keywords covid19
    Publisher WHO
    Document type Article
    Note WHO #Covidence: #767959
    Database COVID19

    Kategorien

  3. Book ; Online: Endotracheal intubation with barrier protection

    Jazuli, Farah / Bilic, Monika / Hanel, Erich / Ha, Michael / Hassall, Kelly / Trotter, Brendon Gordon

    2020  

    Abstract: Given the high risk of healthcare worker (HCW) infection with COVID-19 during aerosol-generating medical procedures, the use of a box barrier during intubation for protection of HCWs has been examined. Previous simulation work has demonstrated its ... ...

    Abstract Given the high risk of healthcare worker (HCW) infection with COVID-19 during aerosol-generating medical procedures, the use of a box barrier during intubation for protection of HCWs has been examined. Previous simulation work has demonstrated its efficacy in protecting HCWs from cough-expelled droplets. Our objective was to assess its ability to protect HCWs against aerosols generated during aerosol-generating medical procedures. We used a battery-powered vapouriser to assess movement of vapour with: (1) no barrier; (2) a box barrier; and (3) a box barrier and a plastic sheet covering the box and patient’s body. We visualised the trajectory of vapour and saw that the vapour remained within the barrier space when the box barrier and plastic sheet were used. This is in contrast to the box barrier alone, where vapour diffused towards the feet of the patient and throughout the room, and to no barrier where the vapour immediately diffused to the laryngoscopist. This demonstrates that the box with the plastic sheet has the potential to limit the spread of aerosols towards the laryngoscopist, and thus may play a role in protecting HCWs during aerosol-generating medical procedures. This is of particular importance in the care of patients with suspected COVID-19.
    Keywords Report from the front ; covid19
    Language English
    Publishing date 2020-07-01 00:00:00.0
    Publisher BMJ Publishing Group Ltd
    Publishing country us
    Document type Book ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  4. Article ; Online: Endotracheal intubation with barrier protection

    Jazuli, Farah / Bilic, Monika / Hanel, Erich / Ha, Michael / Hassall, Kelly / Trotter, Brendon Gordon

    Emergency Medicine Journal

    2020  Volume 37, Issue 7, Page(s) 398–399

    Abstract: Given the high risk of healthcare worker (HCW) infection with COVID-19 during aerosol-generating medical procedures, the use of a box barrier during intubation for protection of HCWs has been examined. Previous simulation work has demonstrated its ... ...

    Abstract Given the high risk of healthcare worker (HCW) infection with COVID-19 during aerosol-generating medical procedures, the use of a box barrier during intubation for protection of HCWs has been examined. Previous simulation work has demonstrated its efficacy in protecting HCWs from cough-expelled droplets. Our objective was to assess its ability to protect HCWs against aerosols generated during aerosol-generating medical procedures. We used a battery-powered vapouriser to assess movement of vapour with: (1) no barrier; (2) a box barrier; and (3) a box barrier and a plastic sheet covering the box and patient’s body. We visualised the trajectory of vapour and saw that the vapour remained within the barrier space when the box barrier and plastic sheet were used. This is in contrast to the box barrier alone, where vapour diffused towards the feet of the patient and throughout the room, and to no barrier where the vapour immediately diffused to the laryngoscopist. This demonstrates that the box with the plastic sheet has the potential to limit the spread of aerosols towards the laryngoscopist, and thus may play a role in protecting HCWs during aerosol-generating medical procedures. This is of particular importance in the care of patients with suspected COVID-19.
    Keywords Critical Care and Intensive Care Medicine ; Emergency Medicine ; General Medicine ; covid19
    Language English
    Publisher BMJ
    Publishing country uk
    Document type Article ; Online
    ZDB-ID 2040124-3
    ISSN 1472-0205
    ISSN 1472-0205
    DOI 10.1136/emermed-2020-209785
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

To top