LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 10 of total 169

Search options

  1. Book: Refractive surface ablation

    Vinciguerra, Paolo

    PRK, LASEK, Epi-LASIK, custom, PTK, and retreatment

    2007  

    Author's details ed. by Paolo Vinciguerra
    Keywords Refractive Errors / surgery ; Cornea / surgery ; Keratectomy, Laser / methods ; Ophthalmologic Surgical Procedures / methods
    Language English
    Size VIII, 351 S. : zahlr. Ill.
    Publisher Slack
    Publishing place Thorofare, NJ
    Publishing country United States
    Document type Book
    HBZ-ID HT014790726
    ISBN 1-55642-713-1 ; 978-1-55642-713-8
    Database Catalogue ZB MED Medicine, Health

    More links

    Kategorien

  2. Book ; Audio / Video: Refractive.on-line, topography.on-line, aberrometry.on-line

    Vinciguerra, Paolo

    Milan (Italy), September 11 - 14, 2002

    (Journal of refractive surgery ; [19,3, Beil.])

    2003  

    Author's details course director Paolo Vinciguerra
    Series title Journal of refractive surgery ; [19,3, Beil.]
    Collection
    Size 1 CD-ROM, 12 cm
    Publishing place S.l.
    Publishing country Italy
    Document type Book ; Audio / Video
    HBZ-ID HT013776008
    Database Catalogue ZB MED Medicine, Health

    Kategorien

  3. Article ; Online: September consultation #3.

    Vinciguerra, Paolo

    Journal of cataract and refractive surgery

    2020  Volume 46, Issue 9, Page(s) 1317–1321

    MeSH term(s) Adult ; Eyeglasses ; Humans ; Referral and Consultation ; Refractive Errors ; Vision Tests
    Language English
    Publishing date 2020-09-03
    Publishing country United States
    Document type Journal Article ; Comment
    ZDB-ID 632744-8
    ISSN 1873-4502 ; 0886-3350
    ISSN (online) 1873-4502
    ISSN 0886-3350
    DOI 10.1097/01.j.jcrs.0000717544.06279.e4
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  4. Book ; Audio / Video: Refractive.on-line, topography.on-line, aberrometry.on-line

    Vinciguerra, Paolo

    Milan (Italy), September 13 - 15, 2001

    2002  

    Author's details course director Paolo Vinciguerra
    Size 1 CD-ROM, 12 cm
    Publishing place S.l.
    Publishing country Italy
    Document type Book ; Audio / Video
    HBZ-ID HT013438394
    Database Catalogue ZB MED Medicine, Health

    Kategorien

  5. Article: Low Rate of Postoperative Pterygium Recurrence in Patients under Treatment with Low-Dose Oral Doxycycline for Chronic Blepharitis: A First Report.

    Catania, Fiammetta / Vinciguerra, Paolo / Di Maria, Alessandra

    Diagnostics (Basel, Switzerland)

    2024  Volume 14, Issue 7

    Abstract: Purpose: Low doses of systemic doxycycline (LD-SD) inhibit angiogenesis and the expression of matrix metalloproteases, which are determinants of pterygium progression. This study aimed to compare the recurrence rate and visual outcome of pterygium ... ...

    Abstract Purpose: Low doses of systemic doxycycline (LD-SD) inhibit angiogenesis and the expression of matrix metalloproteases, which are determinants of pterygium progression. This study aimed to compare the recurrence rate and visual outcome of pterygium excision in patients undergoing chronic treatment with LD-SD for chronic refractory blepharitis and LD-SD-naive patients.
    Methods: A retrospective analysis of patients that underwent surgical excision and conjunctival graft apposition was conducted. Patients were divided in a TETRA group (under LD-SD treatment at the moment of surgery) and a control group. The main outcome was the rate of recurrence at 1 year postoperatively. Secondary outcomes were the comparisons of surface regularity, visual quality, and dry-eye symptoms at 6-week, 6-month, and 1-year follow-up in the two groups.
    Results: The TETRA group showed a significantly lower rate of 1-year recurrence both in primary (
    Conclusions: Patients under treatment with LD-SD showed a lower rate of recurrence at 1-year follow-up compared to controls. These patients also experienced higher BCVA and surface regularity and less dry-eye symptoms.
    Language English
    Publishing date 2024-03-28
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2662336-5
    ISSN 2075-4418
    ISSN 2075-4418
    DOI 10.3390/diagnostics14070715
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  6. Article ; Online: December consultation #9.

    Vinciguerra, Paolo

    Journal of cataract and refractive surgery

    2018  Volume 44, Issue 12, Page(s) 1532–1533

    MeSH term(s) Corneal Surgery, Laser/methods ; Corneal Wavefront Aberration/surgery ; Humans ; Lens Implantation, Intraocular/methods
    Language English
    Publishing date 2018-10-27
    Publishing country United States
    Document type Journal Article
    ZDB-ID 632744-8
    ISSN 1873-4502 ; 0886-3350
    ISSN (online) 1873-4502
    ISSN 0886-3350
    DOI 10.1016/j.jcrs.2018.10.012
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  7. Article ; Online: The Importance of Using CBI-LVC for Detecting Ectasia in Post-Refractive Eyes.

    Ferraro, Vanessa / Ambrósio, Renato / Vinciguerra, Paolo / Vinciguerra, Riccardo

    Beyoglu eye journal

    2023  Volume 8, Issue 3, Page(s) 237–238

    Language English
    Publishing date 2023-09-13
    Publishing country Turkey
    Document type Journal Article
    ZDB-ID 3031466-5
    ISSN 2587-0394 ; 2459-1777
    ISSN (online) 2587-0394
    ISSN 2459-1777
    DOI 10.14744/bej.2023.82542
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  8. Article ; Online: Consultation Section: Refractive. June consultation #5.

    Vinciguerra, Paolo

    Journal of cataract and refractive surgery

    2017  Volume 43, Issue 6, Page(s) 857–858

    MeSH term(s) Refractive Errors
    Language English
    Publishing date 2017-07-21
    Publishing country United States
    Document type Journal Article
    ZDB-ID 632744-8
    ISSN 1873-4502 ; 0886-3350
    ISSN (online) 1873-4502
    ISSN 0886-3350
    DOI 10.1016/j.jcrs.2017.06.014
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  9. Article ; Online: Camellin-Calossi Formula for Intraocular Lens Power Calculation in Patients With Previous Myopic Laser Vision Correction.

    Zollet, Piero / Romeo, Maria Angela / Tripepi, Domenico / Vinciguerra, Paolo / Vinciguerra, Riccardo

    Journal of refractive surgery (Thorofare, N.J. : 1995)

    2024  Volume 40, Issue 3, Page(s) e156–e163

    Abstract: Purpose: To assess the performance of the Camellin-Calossi formula in eyes with prior myopic laser vision correction.: Methods: This was a retrospective case series. Patients included had a history of uncomplicated myopic laser vision correction and ... ...

    Abstract Purpose: To assess the performance of the Camellin-Calossi formula in eyes with prior myopic laser vision correction.
    Methods: This was a retrospective case series. Patients included had a history of uncomplicated myopic laser vision correction and cataract surgery. The primary outcome measures were cumulative distribution of absolute refractive prediction error, absolute refractive prediction error, and refractive prediction error. These parameters were estimated post-hoc using the Camellin-Calossi, Shammas, Haigis-L, Barrett True-K with or without history, Masket, and Modified Masket formulas and their averages starting from biometric data, clinical records, postoperative refraction, and intraocular lens power implanted.
    Results: Seventy-seven eyes from 77 patients were included. The Camellin-Calossi, Shammas, Haigis-L, Barrett True-K No History, Masket, Modified Masket, and Barrett True-K formulas showed a median absolute refractive error (interquartile range) of 0.25 (0.53), 0.51 (0.56), 0.44 (0.65), 0.45 (0.59), 0.40 (0.61), 0.60 (0.70), and 0.55 (0.76), respectively. The proportion of eyes with an absolute refractive error of ±0.25, 0.50, 0.75, 1.00, 1.50, and 2.00 diopters (D) for the Camellin-Calossi formula was 54.5%, 72.7%, 85.7%, 92.2%, 98.7%, and 100%, respectively. The cumulative distribution of the Camellin-Calossi formula showed the best qualitative performances when compared to the others. A statistically significant difference was identified with all of the others except the Haigis-L using a threshold of 0.25, with the Shammas, Modified Masket, and Barrett True-K at a threshold of 0.50 D and the Barrett True-K and Modified Masket at a threshold of 1.00 D.
    Conclusions: The Camellin-Calossi formula is a valid option for intraocular lens power calculation in eyes with prior myopic laser vision correction.
    MeSH term(s) Humans ; Lenses, Intraocular ; Lens Implantation, Intraocular ; Retrospective Studies ; Phacoemulsification ; Refraction, Ocular ; Keratomileusis, Laser In Situ ; Myopia/surgery ; Biometry ; Lasers ; Optics and Photonics
    Language English
    Publishing date 2024-03-01
    Publishing country United States
    Document type Journal Article
    ZDB-ID 1264796-2
    ISSN 1938-2391 ; 0883-0444 ; 1081-597X ; 1081-0803
    ISSN (online) 1938-2391
    ISSN 0883-0444 ; 1081-597X ; 1081-0803
    DOI 10.3928/1081597X-20240208-02
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  10. Article ; Online: Why the Corvis Biomechanical Factor Should Only Be Used for Corneal Ectasia.

    Herber, Robert / Vinciguerra, Riccardo / Flockerzi, Elias / Vinciguerra, Paolo / Seitz, Berthold

    Translational vision science & technology

    2023  Volume 12, Issue 5, Page(s) 24

    MeSH term(s) Humans ; Dilatation, Pathologic ; Cornea
    Language English
    Publishing date 2023-06-23
    Publishing country United States
    Document type Letter ; Comment
    ZDB-ID 2674602-5
    ISSN 2164-2591 ; 2164-2591
    ISSN (online) 2164-2591
    ISSN 2164-2591
    DOI 10.1167/tvst.12.5.24
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top