LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 6 of total 6

Search options

  1. Article: Bioanalytical method development and validation of highly selective and sensitive LC-MS/MS method for determination of teriparatide (parathyroid hormone fragment 1–34) in human serum through direct detection of intact teriparatide molecule

    Kusuma, Manoj Bob / Kashibhatta, Ravisekhar / Gavande, Anil / Kiran, Ravi / Jagtap, Sandeep / Vithala, Praveen / Moorkoth, Sudheer / Bhat, Krishnamurthy

    Journal of chromatography. 2021 Dec. 15, v. 1187

    2021  

    Abstract: Teriparatide is a novel recombinant peptide fragment of the first 1–34 amino acids of human parathyroid recommended for treatment of osteoporosis. Therapeutic proteins and peptides are routinely estimated using ligand binding assay formats however LC-MS/ ... ...

    Abstract Teriparatide is a novel recombinant peptide fragment of the first 1–34 amino acids of human parathyroid recommended for treatment of osteoporosis. Therapeutic proteins and peptides are routinely estimated using ligand binding assay formats however LC-MS/MS technique which is routinely used in bioanalysis of small molecules has now gained importance in large molecule bioanalysis for the advantages it can offer over LBAs in terms of improved accuracy, selectivity and anti-body free method development. This paper presents a sensitive bioanalytical method for determination of teriparatide in human serum using ultra performance liquid chromatography aligned with tandem mass spectrometric detection. Teriparatide was isolated from human serum using solid phase extraction. The intact peptide was separated on a chromatograph and the multiply charged ion (+7) was detected using a mass spectrometer. The total run time was 4.0 min. The internal standard used was rat PTH 1–34 fragment. The mass transitions of m/z 589.3 > 656.3 for teriparatide and m/z 677.4 > 778.6 for internal standard were used for MS/MS detection. The sample extraction involved a solid phase extraction method followed by concentration of the eluent by evaporation and subsequent reconstitution. The non-specific binding effect caused by the adherence of the peptides/proteins to the vials/tube walls was significantly reduced by using BSA solution as blocking agent. The method has been validated over a linear range of 15.07–913.3 pg/mL with a correlation coefficient ≥ 0.99. The precision (%RSD) was 6.36 to 10.85 and accuracy was within 96.71% to 100.88%. A two-treatment, two-period, cross over study was conducted to establish bioequivalence between test and reference formulation (20 mcg/80 mL – solution for injection) and the method was successfully applied to quantify teriparatide in serum samples of this clinical study and about 1220 human serum samples were analyzed to determine teriparatide. This method is a promising anti-body free LC-MS/MS based methodology for estimation of teriparatide in human serum and may be applied as starting method for other such peptide molecules.
    Keywords blood serum ; evaporation ; humans ; ligands ; osteoporosis ; parathyroid hormone ; pharmacokinetics ; rats ; recombinant peptides ; solid phase extraction ; spectrometers ; therapeutics ; ultra-performance liquid chromatography
    Language English
    Dates of publication 2021-1215
    Publishing place Elsevier B.V.
    Document type Article
    ISSN 1570-0232
    DOI 10.1016/j.jchromb.2021.123046
    Database NAL-Catalogue (AGRICOLA)

    More links

    Kategorien

  2. Article ; Online: Corrigendum to "A selective and sensitive UPLC-ESI-MS/MS method for quantification of Pegylated Interferon Alfa-2b in human serum using signature peptide-based quantitation" [J. Chromatogr. B 1180 (2021) 122883].

    Kusuma, Manoj Bob / Kashibhatta, Ravisekhar / Jagtap, Sandeep S / Nadawade, Vijay / Adsul, Suresh / Moorkoth, Sudheer / Bhat, Krishnamurthy / Mody, Rustom / Vithala, Praveen

    Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

    2022  Volume 1192, Page(s) 123159

    Language English
    Publishing date 2022-02-10
    Publishing country Netherlands
    Document type Published Erratum
    ZDB-ID 1180823-8
    ISSN 1873-376X ; 0378-4347 ; 1570-0232 ; 1387-2273
    ISSN (online) 1873-376X
    ISSN 0378-4347 ; 1570-0232 ; 1387-2273
    DOI 10.1016/j.jchromb.2022.123159
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article ; Online: Corrigendum to "Bioanalytical method development and validation of highly selective and sensitive LC-MS/MS method for determination of teriparatide (parathyroid hormone fragment 1-34) in human serum through direct detection of intact teriparatide molecule" [J. Chromatogr. B 1187 (2021) 123046].

    Kusuma, Manoj Bob / Kashibhatta, Ravisekhar / Gavande, Anil / Kiran, Ravi / Jagtap, Sandeep / Vithala, Praveen / Moorkoth, Sudheer / Bhat, Krishnamurthy

    Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

    2022  Volume 1192, Page(s) 123158

    Language English
    Publishing date 2022-02-10
    Publishing country Netherlands
    Document type Published Erratum
    ZDB-ID 1180823-8
    ISSN 1873-376X ; 0378-4347 ; 1570-0232 ; 1387-2273
    ISSN (online) 1873-376X
    ISSN 0378-4347 ; 1570-0232 ; 1387-2273
    DOI 10.1016/j.jchromb.2022.123158
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  4. Article ; Online: Bioanalytical method development and validation of highly selective and sensitive LC-MS/MS method for determination of teriparatide (parathyroid hormone fragment 1-34) in human serum through direct detection of intact teriparatide molecule.

    Kusuma, Manoj Bob / Kashibhatta, Ravisekhar / Gavande, Anil / Kiran, Ravi / Jagtap, Sandeep / Vithala, Praveen / Moorkoth, Sudheer / Bhat, Krishnamurthy

    Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

    2021  Volume 1187, Page(s) 123046

    Abstract: Teriparatide is a novel recombinant peptide fragment of the first 1-34 amino acids of human parathyroid recommended for treatment of osteoporosis. Therapeutic proteins and peptides are routinely estimated using ligand binding assay formats however LC-MS/ ... ...

    Abstract Teriparatide is a novel recombinant peptide fragment of the first 1-34 amino acids of human parathyroid recommended for treatment of osteoporosis. Therapeutic proteins and peptides are routinely estimated using ligand binding assay formats however LC-MS/MS technique which is routinely used in bioanalysis of small molecules has now gained importance in large molecule bioanalysis for the advantages it can offer over LBAs in terms of improved accuracy, selectivity and anti-body free method development. This paper presents a sensitive bioanalytical method for determination of teriparatide in human serum using ultra performance liquid chromatography aligned with tandem mass spectrometric detection. Teriparatide was isolated from human serum using solid phase extraction. The intact peptide was separated on a chromatograph and the multiply charged ion (+7) was detected using a mass spectrometer. The total run time was 4.0 min. The internal standard used was rat PTH 1-34 fragment. The mass transitions of m/z 589.3 > 656.3 for teriparatide and m/z 677.4 > 778.6 for internal standard were used for MS/MS detection. The sample extraction involved a solid phase extraction method followed by concentration of the eluent by evaporation and subsequent reconstitution. The non-specific binding effect caused by the adherence of the peptides/proteins to the vials/tube walls was significantly reduced by using BSA solution as blocking agent. The method has been validated over a linear range of 15.07-913.3 pg/mL with a correlation coefficient ≥ 0.99. The precision (%RSD) was 6.36 to 10.85 and accuracy was within 96.71% to 100.88%. A two-treatment, two-period, cross over study was conducted to establish bioequivalence between test and reference formulation (20 mcg/80 mL - solution for injection) and the method was successfully applied to quantify teriparatide in serum samples of this clinical study and about 1220 human serum samples were analyzed to determine teriparatide. This method is a promising anti-body free LC-MS/MS based methodology for estimation of teriparatide in human serum and may be applied as starting method for other such peptide molecules.
    MeSH term(s) Chromatography, High Pressure Liquid/methods ; Humans ; Limit of Detection ; Linear Models ; Reproducibility of Results ; Solid Phase Extraction ; Tandem Mass Spectrometry/methods ; Teriparatide/blood ; Teriparatide/chemistry
    Chemical Substances Teriparatide (10T9CSU89I)
    Language English
    Publishing date 2021-11-17
    Publishing country Netherlands
    Document type Journal Article
    ZDB-ID 1180823-8
    ISSN 1873-376X ; 0378-4347 ; 1570-0232 ; 1387-2273
    ISSN (online) 1873-376X
    ISSN 0378-4347 ; 1570-0232 ; 1387-2273
    DOI 10.1016/j.jchromb.2021.123046
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  5. Article ; Online: A selective and sensitive UPLC-ESI-MS/MS method for quantification of Pegylated Interferon Alfa-2b in human serum using signature peptide-based quantitation.

    Bob Kusuma, Manoj / Kashibhatta, Ravisekhar / Jagtap, Sandeep S / Nadawade, Vijay / Adsul, Suresh / Moorkoth, Sudheer / Bhat, Krishnamurthy / Mody, Rustom / Vithala, Praveen

    Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

    2021  Volume 1180, Page(s) 122883

    Abstract: A sensitive method for determination of PEG-IFN-α-2b in human serum was developed using ultra performance liquid chromatography aligned with tandem mass spectrometric detection. A two-treatment, two-period, cross over study was conducted to establish ... ...

    Abstract A sensitive method for determination of PEG-IFN-α-2b in human serum was developed using ultra performance liquid chromatography aligned with tandem mass spectrometric detection. A two-treatment, two-period, cross over study was conducted to establish bioequivalence between a test and reference formulation and the method was successfully applied to the quantification of PEG-IFN-α-2b in serum samples of this clinical study. The sample concentrations obtained from LC-MS/MS technique were compared with the concentrations obtained from ELISA technique. PEG-IFN-α-2b was isolated from serum using protein precipitation technique with isopropyl alcohol followed by overnight tryptic digestion. The signature peptide formed as result of tryptic digestion was separated on a chromatograph and detected using a mass detector. The mass transition ion-pair of m/z 741.3 → 1047.1 for PEG-IFN-α-2b and m/z 387.4 → 205.2 for internal standard were used for MS/MS detection. The sample extraction involves a simple protein precipitation method followed by tryptic digestion of the supernatant and further sample cleanup was not needed. The method has been validated over a linear range of 1.028-3200 ng/mL with a correlation coefficient ≥ 0.99. The precision (%RSD) was 5.52 to 7.90 and accuracy (%RE) was within -1.80 to 1.68. The total run time was 22.0 min. The sensitivity of LC-MS/MS method was 1.0 ng/ml which was found to be more sensitive than ELISA and resulted in improving the overall study data by being able to quantify all the samples without any below LOQ results helping to further improve the pharmacokinetic modeling. This improved method is a promising anti-body free LC-MS/MS based methodology for estimation of PEG-IFN-α-2b in human serum and may be applied for other such pegylated molecules.
    MeSH term(s) Chromatography, High Pressure Liquid/methods ; Cross-Over Studies ; Humans ; Interferon alpha-2/blood ; Interferon alpha-2/pharmacokinetics ; Interferon-alpha/blood ; Interferon-alpha/pharmacokinetics ; Limit of Detection ; Linear Models ; Peptide Fragments/blood ; Peptide Fragments/metabolism ; Polyethylene Glycols/pharmacokinetics ; Recombinant Proteins/blood ; Recombinant Proteins/pharmacokinetics ; Reproducibility of Results ; Spectrometry, Mass, Electrospray Ionization/methods ; Tandem Mass Spectrometry/methods ; Therapeutic Equivalency ; Trypsin/metabolism
    Chemical Substances Interferon alpha-2 ; Interferon-alpha ; Peptide Fragments ; Recombinant Proteins ; Polyethylene Glycols (3WJQ0SDW1A) ; Trypsin (EC 3.4.21.4) ; peginterferon alfa-2b (G8RGG88B68)
    Language English
    Publishing date 2021-07-29
    Publishing country Netherlands
    Document type Journal Article
    ZDB-ID 1180823-8
    ISSN 1873-376X ; 0378-4347 ; 1570-0232 ; 1387-2273
    ISSN (online) 1873-376X
    ISSN 0378-4347 ; 1570-0232 ; 1387-2273
    DOI 10.1016/j.jchromb.2021.122883
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  6. Article: A selective and sensitive UPLC–ESI-MS/MS method for quantification of Pegylated Interferon Alfa-2b in human serum using signature peptide-based quantitation

    Bob Kusuma, Manoj / Kashibhatta, Ravisekhar / Jagtap, Sandeep S. / Nadawade, Vijay / Adsul, Suresh / Moorkoth, Sudheer / Bhat, Krishnamurthy / Mody, Rustom / Vithala, Praveen

    Journal of chromatography. 2021 Aug. 15, v. 1180

    2021  

    Abstract: A sensitive method for determination of PEG-IFN-α-2b in human serum was developed using ultra performance liquid chromatography aligned with tandem mass spectrometric detection. A two-treatment, two-period, cross over study was conducted to establish ... ...

    Abstract A sensitive method for determination of PEG-IFN-α-2b in human serum was developed using ultra performance liquid chromatography aligned with tandem mass spectrometric detection. A two-treatment, two-period, cross over study was conducted to establish bioequivalence between a test and reference formulation and the method was successfully applied to the quantification of PEG-IFN-α-2b in serum samples of this clinical study. The sample concentrations obtained from LC-MS/MS technique were compared with the concentrations obtained from ELISA technique. PEG-IFN-α-2b was isolated from serum using protein precipitation technique with isopropyl alcohol followed by overnight tryptic digestion. The signature peptide formed as result of tryptic digestion was separated on a chromatograph and detected using a mass detector. The mass transition ion-pair of m/z 741.3 → 1047.1 for PEG-IFN-α-2b and m/z 387.4 → 205.2 for internal standard were used for MS/MS detection. The sample extraction involves a simple protein precipitation method followed by tryptic digestion of the supernatant and further sample cleanup was not needed. The method has been validated over a linear range of 1.028–3200 ng/mL with a correlation coefficient ≥ 0.99. The precision (%RSD) was 5.52 to 7.90 and accuracy (%RE) was within −1.80 to 1.68. The total run time was 22.0 min. The sensitivity of LC-MS/MS method was 1.0 ng/ml which was found to be more sensitive than ELISA and resulted in improving the overall study data by being able to quantify all the samples without any below LOQ results helping to further improve the pharmacokinetic modeling. This improved method is a promising anti-body free LC-MS/MS based methodology for estimation of PEG-IFN-α-2b in human serum and may be applied for other such pegylated molecules.
    Keywords blood serum ; digestion ; humans ; interferons ; isopropyl alcohol ; peptides ; pharmacokinetics ; ultra-performance liquid chromatography
    Language English
    Dates of publication 2021-0815
    Publishing place Elsevier B.V.
    Document type Article
    ISSN 1570-0232
    DOI 10.1016/j.jchromb.2021.122883
    Database NAL-Catalogue (AGRICOLA)

    More links

    Kategorien

To top