LIVIVO - Das Suchportal für Lebenswissenschaften

switch to English language
Erweiterte Suche

Ihre letzten Suchen

  1. AU="Viviane M. Parra"
  2. AU="Kushner, Adam"
  3. AU="Claude Pasquier"
  4. AU="Guomin Zhang"
  5. AU=van der Donk Lieve E H
  6. AU="Reynaerts, Audrey"
  7. AU="Alberts, Susan C"
  8. AU="Kosicki, Jakub Z"
  9. AU=Eifling Michael
  10. AU="Xing, Xinxin"
  11. AU="Baigun, Claudio"
  12. AU="Abu-Hamad, Ghassan"
  13. AU="Mulla, Zuber D"
  14. AU="Schröder, H"
  15. AU=Ruiz Michael Anthony
  16. AU="Kemmoku, Haruka"
  17. AU="Meseguer, M"
  18. AU="Pillaye, Jayshree"
  19. AU="Andrew Pettitt"
  20. AU="Malawski, M"
  21. AU=Marhofer P
  22. AU=Mandel H G
  23. AU="Duffy, Richard"
  24. AU=Kaseb Hatem AU=Kaseb Hatem
  25. AU=Kong Tak?kwan AU=Kong Tak?kwan
  26. AU=Nagaraja Sridevi
  27. AU="Bu, Yingzi"
  28. AU=Seddighi Hamed AU=Seddighi Hamed
  29. AU="De Keyser, Johan"
  30. AU="Zhenqiang Bi"
  31. AU=Wang Jun
  32. AU=Zhang Fuping
  33. AU="Shatilov, D N"

Suchergebnis

Treffer 1 - 2 von insgesamt 2

Suchoptionen

  1. Artikel ; Online: Estudo de caso

    Viviane M. Parra / Carla G. Matas / Ivone F. Neves

    Revista Brasileira de Otorrinolaringologia, Vol 69, Iss 2, Pp 283-

    neuropatia auditiva Auditory neuropathy: a study case

    2003  Band 288

    Abstract: Atualmente, podemos complementar os resultados encontrados na audiometria convencional com os obtidos nos exames eletrofisiológicos, o que nos permite diagnosticar não apenas uma perda auditiva periférica, mas também diferenciar uma perda auditiva ... ...

    Abstract Atualmente, podemos complementar os resultados encontrados na audiometria convencional com os obtidos nos exames eletrofisiológicos, o que nos permite diagnosticar não apenas uma perda auditiva periférica, mas também diferenciar uma perda auditiva coclear da neural, ou central. Isto nos conduziu a um grupo novo de pacientes que apresentava alteração na sincronia neural com função normal das células ciliadas externas. Esta patologia é conhecida como Neuropatia Auditiva. O objetivo deste estudo é descrever as características audiológicas de um paciente com Neuropatia Auditiva atendido no Centro de Docência e Pesquisa em Fonoaudiologia da Faculdade de Medicina da Universidade de São Paulo (FMUSP), correlacionando os achados com os encontrados na literatura. O caso descrito é de um indivíduo de 24 anos de idade, com o diagnóstico de Neuropatia Auditiva, atendido no ano de 2001 no Centro de Docência e Pesquisa em Fonoaudiologia da FMUSP. Foram realizados anamnese, audiometria tonal e vocal, medidas de imitância acústica, Emissões Otoacústicas (EOAs) e Audiometria de Tronco Encefálico (ABR). Observamos no caso estudado a incompatibilidade de resultados entre audiometria tonal e testes de inteligibilidade de fala, com os exames objetivos, EOAs e ABR, onde observou-se perda auditiva com importante alteração nos testes de inteligibilidade de fala, EOAs presentes e ABR anormal. Estes dados sugerem função coclear normal e alteração da sincronia neural. Nowadays, in our clinic, we can complement the conventional audiometry results with electrophysiologic exams. Not only does allow us to diagnose a peripheral hearing loss but also to differentiate cochlear, neural or central hearing loss. It led us to a new group of patients that presented changes in neural synchrony, with normal functions of the outer ear hair cells. This pathology is known as Auditory Neuropathy. Our study purpose is describe the audiologist characteristic of a patient with auditory neuropathy attended at "Centro de Docência e Pesquisa em Fonoaudiologia da Faculdade de Medicina da Universidade de São Paulo", correlating the study data with literature. The patient described is a 24 year-old person, with auditory neuropathy diagnosis, evaluated in our center in 2001. Interview, tonal audiometry thresholds, speech recognition, timpanometry, otoacustic emissions (OAEs) and auditory brainstem responses (ABR) were applied. In this case we observed incompatible results in the tonal audiometric threshold and speech recognition tests, with objectives tests like OAEs and ABR, in which we found a hearing loss with important changes in the speech recognition test, of OAEs present and abnormal ABR. These data suggest a normal cochlear function and abnormal neural synchrony.
    Schlagwörter neuropatia auditiva ; audição ; testes auditivos ; auditory neuropathy ; hearing ; hearing tests ; Otorhinolaryngology ; RF1-547 ; Medicine ; R ; DOAJ:Otorhinolaryngology ; DOAJ:Medicine (General) ; DOAJ:Health Sciences
    Sprache Portugiesisch
    Erscheinungsdatum 2003-03-01T00:00:00Z
    Verlag Sociedade Brasileira de Otorrinolaringologia
    Dokumenttyp Artikel ; Online
    Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

    Zusatzmaterialien

    Kategorien

  2. Artikel ; Online: Testes de padrão de freqüência e de duração em idosos com sensibilidade auditiva normal Frequency and duration patterns tests in elderly people with normal hearing sensitivity

    Viviane M. Parra / Maria Cecília M. Iório / Mary M. Mizahi / Giovana dos S. Baraldi

    Revista Brasileira de Otorrinolaringologia, Vol 70, Iss 4, Pp 517-

    2004  Band 523

    Abstract: Estudos atuais apontam para o fato que o indivíduo idoso pode apresentar uma desordem do processamento auditivo mesmo sem haver uma lesão estrutural que a explique diretamente. OBJETIVO: Caracterizar o desempenho de idosos com sensibilidade auditiva ... ...

    Abstract Estudos atuais apontam para o fato que o indivíduo idoso pode apresentar uma desordem do processamento auditivo mesmo sem haver uma lesão estrutural que a explique diretamente. OBJETIVO: Caracterizar o desempenho de idosos com sensibilidade auditiva normal no Teste de Padrão de Freqüência (TPF) e de Padrão de Duração (TPD). FORMA DE ESTUDO: Clínico prospectivo. MÉTODO: A amostra contou com 25 idosos com audição normal e sem história de comprometimentos centrais. Foram realizados os Testes de Padrão de Duração e Teste de Padrão de Freqüência a 50dBNS, sendo solicitada resposta através de nomeação. RESULTADOS: Não foram encontradas diferenças nos dois testes, segundo a variável lado da orelha. A porcentagem média de acertos obtida no Teste de Padrão de Duração foi de 67,5% e no Teste de Padrão de Freqüência foi de 49,2%. A correlação entre os testes TPD e TPF e a idade dos pacientes mostrou-se inversamente proporcional, ou seja, quanto maior a idade pior o desempenho nos testes, sendo que a maior correlação foi encontrada no Teste de Padrão de Duração. CONCLUSÃO: Não foram observadas diferenças segundo a variável lado da orelha e os indivíduos idosos com sensibilidade auditiva normal apresentam uma porcentagem média de acertos de 47,2% no Teste de Padrão de Freqüência de 67,5% no Teste de Padrão Duração. Current studies indicate the fact that elderly individuals may present a hearing processing disorder even without a structural lesion explaining it directly. AIM: To characterize the performance of elderly people with normal hearing sensitivity in the Frequency Standard and Duration Patterns Tests. STUDY DESIGN: Clinical prospective. METHOD: The sample counted on 25 elderly people with normal hearing and without history of central impairments. The Duration Pattern Test and the Frequency Pattern Test were carried out at 50 dBNS, with the request of answers through indication. RESULTS: The statistical analysis has shown that neither the ear side (right or left). The correct answer percentages found in the Duration Pattern Test was 67.5 and in the Frequency Pattern Test was 49.2. CONCLUSION: Statistic differences between the ears (right or left) were not found. The elderly individuals with normal hearing sensitivity present an average percentage of correct answers of 47.2% in the Frequency Pattern Test and of 67.5% in the Duration Pattern Test. The percentile values 3 and 97 were 23% and 96% for the Duration Pattern Test and of 17% and 98% for the Frequency Pattern Test, respectively.
    Schlagwörter processamento auditivo central ; testes tonais de padrão de freqüência ; testes de padrão de duração ; central auditory processing ; pitch pattern test ; duration pattern test ; Medicine ; R ; Otorhinolaryngology ; RF1-547
    Sprache Englisch
    Erscheinungsdatum 2004-08-01T00:00:00Z
    Verlag Sociedade Brasileira de Otorrinolaringologia
    Dokumenttyp Artikel ; Online
    Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

    Zusatzmaterialien

    Kategorien

Zum Seitenanfang