LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 7 of total 7

Search options

  1. Article ; Online: Supramolecular fluorescence sensor array used for the analysis of tyrosine kinase inhibitors in biological fluids and cell imaging.

    Yi, Hong-Ling / Yang, Ru-Pei / Tang, Qing / Tao, Zhu / Huang, Ying

    Analytica chimica acta

    2023  Volume 1287, Page(s) 342124

    Abstract: Tyrosine kinase inhibitors (TKIs) are commonly used in tumor targeting therapy. However, the rapid analysis of TKIs remains a significant challenge, especially in complex biological fluid environments. In this work, we have constructed a supramolecular ... ...

    Abstract Tyrosine kinase inhibitors (TKIs) are commonly used in tumor targeting therapy. However, the rapid analysis of TKIs remains a significant challenge, especially in complex biological fluid environments. In this work, we have constructed a supramolecular fluorescence sensor array based on a cucurbituril-dye host-guest complex. The binding affinity between the three complexes and each TKI is different, resulting in different cross-response signals of the complexes to the fluorescence of each TKI. Combined with linear discriminant analysis(LDA), five kinds of TKIs can be well identified. The supramolecular fluorescence sensor array could accurately identify and distinguish the five TKIs in water and could classify mixtures containing different concentrations of TKIs in serum. The concentration and Factor 1 exhibited a good linear relationship and the detection limit (LOD) was as low as 10
    MeSH term(s) Reproducibility of Results ; Tyrosine Kinase Inhibitors ; Cell Differentiation ; Discriminant Analysis ; Drug Monitoring
    Chemical Substances Tyrosine Kinase Inhibitors
    Language English
    Publishing date 2023-12-09
    Publishing country Netherlands
    Document type Journal Article
    ZDB-ID 1483436-4
    ISSN 1873-4324 ; 0003-2670
    ISSN (online) 1873-4324
    ISSN 0003-2670
    DOI 10.1016/j.aca.2023.342124
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article ; Online: Supramolecular fluorescent probe based on a host-guest complex for amino acids recognition and detection in aqueous solution.

    Chen, Xing-Xing / Huang, Shu-Zhen / Yang, Ru-Pei / Huang, Ying / Tang, Qing

    Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy

    2023  Volume 302, Page(s) 123079

    Abstract: A supramolecular fluorescent probe based on a host-guest complex has been developed for amino acid recognition and detection in aqueous solution. Cucurbit[7]uril (Q[7]) with 4-(4-dimethylamino-styrene) quinoline (DSQ) formed a fluorescent probe (DSQ@Q[7]) ...

    Abstract A supramolecular fluorescent probe based on a host-guest complex has been developed for amino acid recognition and detection in aqueous solution. Cucurbit[7]uril (Q[7]) with 4-(4-dimethylamino-styrene) quinoline (DSQ) formed a fluorescent probe (DSQ@Q[7]). The DSQ@Q[7] fluorescent probe nearly generated changes in fluorescence in response to four amino acids (arginine, histidine, phenylalanine and tryptophan). These changes were attributed to the host-guest interaction between DSQ@Q[7] and amino acids, which occurred as a consequence of the subtle cooperation of ionic dipole and hydrogen bonding. Linear discriminant analysis showed that the fluorescent probe could recognize and distinguish four amino acids, and a mixture with different concentration ratios could be well categorized in ultrapure water and tap water.
    MeSH term(s) Amino Acids/chemistry ; Fluorescent Dyes/chemistry ; Phenylalanine/analysis ; Histidine ; Water/chemistry
    Chemical Substances Amino Acids ; Fluorescent Dyes ; Phenylalanine (47E5O17Y3R) ; Histidine (4QD397987E) ; Water (059QF0KO0R)
    Language English
    Publishing date 2023-06-28
    Publishing country England
    Document type Journal Article
    ZDB-ID 210413-1
    ISSN 1873-3557 ; 0370-8322 ; 0584-8539 ; 1386-1425
    ISSN (online) 1873-3557
    ISSN 0370-8322 ; 0584-8539 ; 1386-1425
    DOI 10.1016/j.saa.2023.123079
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article ; Online: Supramolecular Fluorescence Sensor Array Based on Cucurbit[8]uril Complexes Used for the Detection of Multiplex Quaternary Ammonium Pesticides.

    Wei, Kai-Ni / Yang, Ru-Pei / Huang, Shu-Zhen / Tao, Zhu / Tang, Qing / Huang, Ying

    Journal of agricultural and food chemistry

    2023  Volume 71, Issue 24, Page(s) 9549–9557

    Abstract: The simultaneous detection of multiple quaternary ammonium pesticides (QAPs) in water is a challenge due to their high solubility in water and similar structures. In this paper, we have developed a quadruple-channel supramolecular fluorescence sensor ... ...

    Abstract The simultaneous detection of multiple quaternary ammonium pesticides (QAPs) in water is a challenge due to their high solubility in water and similar structures. In this paper, we have developed a quadruple-channel supramolecular fluorescence sensor array for the simultaneous analysis of five QAPs, including paraquat (PQ), diquat (DQ), difenzoquat (DFQ), mepiquat (MQ), and chlormequat (CQ). Not only were QAP samples of different concentrations (10, 50, and 300 μM) in water distinguished with 100% accuracy but also single QAP and binary QAP mixed samples (DFQ-DQ) were sensitively quantified. Our experimental interference study confirmed that the developed array has good anti-interference ability. The array can quickly identify five QAPs in river and tap water samples. In addition, it also qualitatively detected QAP residues in Chinese cabbage and wheat seedlings extract. This array has rich output signals, low cost, easy preparation, and simple technology, demonstrating great potential in environmental analysis.
    MeSH term(s) Pesticides/analysis ; Ammonium Compounds ; Fluorescence ; Diquat ; Water
    Chemical Substances Pesticides ; Ammonium Compounds ; cucurbit(8)uril ; Diquat (A9A615U4MP) ; Water (059QF0KO0R)
    Language English
    Publishing date 2023-06-08
    Publishing country United States
    Document type Journal Article
    ZDB-ID 241619-0
    ISSN 1520-5118 ; 0021-8561
    ISSN (online) 1520-5118
    ISSN 0021-8561
    DOI 10.1021/acs.jafc.3c00347
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  4. Article ; Online: A supramolecular fluorescence array sensor for toxic heavy metal ion detection in environmental water and rice seedling extracts.

    Yang, Ru-Pei / Huang, Shu-Zhen / Wei, Kai-Ni / Tang, Qing / Tao, Zhu / Huang, Ying / Zhao, An-Ting

    Dalton transactions (Cambridge, England : 2003)

    2023  Volume 52, Issue 21, Page(s) 7279–7289

    Abstract: A supramolecular fluorescence array sensor based on cucurbituril-dye host-guest complexes (6-QAA@Q[7], PyY@Q[7], and TO@Q[8]) was constructed. The results showed that it can quickly identify and detect toxic heavy metal ions, such as ... ...

    Abstract A supramolecular fluorescence array sensor based on cucurbituril-dye host-guest complexes (6-QAA@Q[7], PyY@Q[7], and TO@Q[8]) was constructed. The results showed that it can quickly identify and detect toxic heavy metal ions, such as Ag
    MeSH term(s) Metals, Heavy/chemistry ; Oryza ; Seedlings/chemistry ; Water/chemistry ; Fluorescence
    Chemical Substances Metals, Heavy ; Water (059QF0KO0R)
    Language English
    Publishing date 2023-05-30
    Publishing country England
    Document type Journal Article
    ZDB-ID 1472887-4
    ISSN 1477-9234 ; 1364-5447 ; 0300-9246 ; 1477-9226
    ISSN (online) 1477-9234 ; 1364-5447
    ISSN 0300-9246 ; 1477-9226
    DOI 10.1039/d3dt00995e
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  5. Article ; Online: A white-light-emitting sensor array based on cucurbit[8]uril for quantitative detection of multicomponent nitroaniline isomers.

    Huang, Shu-Zhen / Wei, Kai-Ni / Yang, Ru-Pei / Yi, Hong-Ling / Tang, Qing / Tao, Zhu / Huang, Ying

    Mikrochimica acta

    2023  Volume 190, Issue 12, Page(s) 460

    Abstract: A white-light-emitting supramolecular complex through supramolecular interactions has been assembled; the white luminescent supramolecular complex exhibits two emission spectra. Based on this, a dual-channel white-light array sensor was constructed. The ... ...

    Abstract A white-light-emitting supramolecular complex through supramolecular interactions has been assembled; the white luminescent supramolecular complex exhibits two emission spectra. Based on this, a dual-channel white-light array sensor was constructed. The results show that it can quickly identify and detect nitroaniline isomer pollutants (p-nitroaniline, m-nitroaniline, o-nitroaniline). When these three nitroaniline isomers were added to the supramolecular white-light array sensor, the fluorescence intensity of the white-light complex decreased to varying degrees. Linear discriminant analysis (LDA) showed that the supramolecular white-light array sensor could recognize and distinguish three nitroaniline isomers and could classify mixtures containing different concentrations. Factor 1 of the array had a good linear relationship with the concentration of pollutants, and the detection limit (LOD) was as low as 0.7 μM. The method has good reproducibility and stability. In addition, it can also qualitatively detect the nitroaniline isomers in river water and contaminated rice seedling extract. It provides an ideal platform for constructing multiresponse sensors.
    Language English
    Publishing date 2023-11-04
    Publishing country Austria
    Document type Journal Article
    ZDB-ID 89-9
    ISSN 1436-5073 ; 0026-3672
    ISSN (online) 1436-5073
    ISSN 0026-3672
    DOI 10.1007/s00604-023-06040-2
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  6. Article ; Online: A colorimetric supramolecular sensor array based on charge-transfer complexes for multiplex aniline and phenolic pollutants detection.

    Huang, Shu-Zhen / Tang, Qing / Wei, Kai-Ni / Yang, Ru-Pei / Tao, Zhu / Huang, Ying / Xiao, Xin

    Analytica chimica acta

    2022  Volume 1233, Page(s) 340504

    Abstract: In order to effectively monitor toxic and harmful substances in sewage discharge, a rapid, highly sensitive detection of complex pollutants with similar structures has become an urgent problem to be solved. In this paper, a supramolecular colorimetric ... ...

    Abstract In order to effectively monitor toxic and harmful substances in sewage discharge, a rapid, highly sensitive detection of complex pollutants with similar structures has become an urgent problem to be solved. In this paper, a supramolecular colorimetric array sensor based on charge-transfer complex was constructed, which can quickly detect aniline and phenol pollutants (such as p-phenylenediamine, m-phenylenediamine, o-phenylenediamine, m-aminophenol, hydroquinone, and resorcinol) with similar structures. When six anilines and phenol isomers with similar structures were added to the supramolecular colorimetric array sensor, different color changes were produced under natural light. Linear discriminant analysis (LDA) showed that the supramolecular colorimetric array sensor could recognize and distinguish these isomers, and a mixture with different concentration ratios could be well categorized. The total Euclidean distance (TED) of an array with pollutant concentrations had a good linear correlation, and the detection limit (LOD) was as low as 10
    MeSH term(s) Colorimetry/methods ; Hydroquinones ; Environmental Pollutants ; Sewage ; Aniline Compounds ; Resorcinols
    Chemical Substances aniline (SIR7XX2F1K) ; Hydroquinones ; Environmental Pollutants ; Sewage ; Aniline Compounds ; Resorcinols
    Language English
    Publishing date 2022-10-11
    Publishing country Netherlands
    Document type Journal Article
    ZDB-ID 1483436-4
    ISSN 1873-4324 ; 0003-2670
    ISSN (online) 1873-4324
    ISSN 0003-2670
    DOI 10.1016/j.aca.2022.340504
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  7. Article ; Online: An outbreak of type π vaccine-derived poliovirus in Sichuan province, China: emergence and circulation in an under-immunized population.

    Wang, Hai-Bo / Fang, Gang / Yu, Wen-Zhou / Du, Fei / Fan, Chun-Xiang / Liu, Qing-Lian / Hao, Li-Xin / Liu, Yu / Zheng, Jing-Shan / Qin, Zhi-Ying / Xia, Wei / Zhang, Shi-Yue / Yin, Zun-Dong / Jing, Qiong / Zhang, Yan-Xia / Huang, Rong-Na / Yang, Ru-Pei / Tong, Wen-Bin / Qi, Qi /
    Guan, Xu-Jing / Jing, Yu-Lin / Ma, Qian-Li / Wang, Jin / Ma, Xiao-Zhen / Chen, Na / Zheng, Hong-Ru / Li, Yin-Qiao / Ma, Chao / Su, Qi-Ru / Reilly, Kathleen H / Luo, Hui-Ming / Wu, Xian-Ping / Wen, Ning / Yang, Wei-Zhong

    PloS one

    2014  Volume 9, Issue 12, Page(s) e113880

    Abstract: Background: During August 2011-February 2012, an outbreak of type Π circulating vaccine-derived poliovirus (cVDPVs) occurred in Sichuan Province, China.: Methods: A field investigation of the outbreak was conducted to characterize outbreak isolates ... ...

    Abstract Background: During August 2011-February 2012, an outbreak of type Π circulating vaccine-derived poliovirus (cVDPVs) occurred in Sichuan Province, China.
    Methods: A field investigation of the outbreak was conducted to characterize outbreak isolates and to guide emergency response. Sequence analysis of poliovirus capsid protein VP1 was performed to determine the viral propagation, and a coverage survey was carried out for risk assessment.
    Results: One clinical compatible polio case and three VDPV cases were determined in Ngawa County, Ngawa Tibetan and Qiang Autonomous Prefecture, Sichuan Province. Case patients were unimmunized children, 0.8-1 years old. Genetic sequencing showed that the isolates diverged from the VP1 region of the type Π Sabin strain by 5-12 nucleotides (nt) and shared the same 5 nt VP1 substitutions, which indicate single lineage of cVDPVs. Of the 7 acute flaccid paralysis cases (all>6 months) reported in Ngawa Prefecture in 2011, 4 (57.1%) cases (including 2 polio cases) did not receive oral attenuated poliovirus vaccine. Supplementary immunization activities (SIAs) were conducted in February-May, 2012, and the strain has not been isolated since.
    Conclusion: High coverage of routine immunization should be maintained among children until WPV transmission is globally eradicated. Risk assessments should be conducted regularly to pinpoint high risk areas or subpopulations, with SIAs developed if necessary.
    MeSH term(s) Adolescent ; Child ; Child, Preschool ; China/epidemiology ; Disease Outbreaks/prevention & control ; Female ; Humans ; Immunization/statistics & numerical data ; Infant ; Male ; Paralysis/epidemiology ; Poliomyelitis/epidemiology ; Poliomyelitis/prevention & control ; Poliomyelitis/transmission ; Poliovirus/immunology ; Poliovirus/physiology ; Poliovirus Vaccines/immunology
    Chemical Substances Poliovirus Vaccines
    Language English
    Publishing date 2014
    Publishing country United States
    Document type Case Reports ; Journal Article
    ISSN 1932-6203
    ISSN (online) 1932-6203
    DOI 10.1371/journal.pone.0113880
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top