LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 2 of total 2

Search options

  1. Article ; Online: Reliability of muscle stiffness measures in popliteus, medial and lateral gastrocnemius muscles by ultrasound shear wave elastography in participants with knee osteoarthritis accompanied by myofascial trigger points.

    Shams, Mohsen / Karimi, Noureddin / Vahedi, Mohsen / Hakim, Peyman Kamali / Zeinalkhani, Fahimeh / Rahnama, Leila

    BMC musculoskeletal disorders

    2024  Volume 25, Issue 1, Page(s) 221

    Abstract: Background: The objective of this investigation is to evaluate the consistency of intra-rater and inter-rater assessments utilizing ultrasound elastography to examine the muscle stiffness of the popliteus and gastrocnemius (medial and lateral heads) in ... ...

    Abstract Background: The objective of this investigation is to evaluate the consistency of intra-rater and inter-rater assessments utilizing ultrasound elastography to examine the muscle stiffness of the popliteus and gastrocnemius (medial and lateral heads) in patients with knee osteoarthritis accompanied by myofascial trigger points.
    Methods: Thirty individuals with knee osteoarthritis accompanied by myofascial trigger points were assessed. Two examiners independently measured the muscle stiffness levels of the popliteus and gastrocnemius (medial and lateral heads) three times using ultrasound elastography in the first session. The second session was conducted one week later.
    Results: In the initial test session, the mean shear modulus values for the popliteus and gastrocnemius (medial and lateral heads) muscles were measured as follows for tester 1 (12.75, 13.72, 14.13 kPa) and tester 2 (11.66, 12.81, 13.17 kPa). During the retest session, the previously measured variables by tester 1 and tester 2 yielded the following values: (12.61, 13.43, 14.26 kPa) and (11.62, 12.87, 13.30 kPa) respectively." Good to excellent intra-rater reliability (ICC = 0.912-0.986) and inter-rater reliability (ICC = 0.766-0.956) were reported for the shear moduli of the popliteus, medial and lateral gastrocnemius muscles.
    Conclusions: The assessment of muscle stiffness in the popliteus and gastrocnemius (medial and lateral heads) using ultrasound elastography is a reliable method in patients with knee osteoarthritis accompanied by myofascial trigger points.
    MeSH term(s) Humans ; Trigger Points ; Elasticity Imaging Techniques/methods ; Osteoarthritis, Knee/diagnostic imaging ; Reproducibility of Results ; Muscle, Skeletal/diagnostic imaging ; Muscle, Skeletal/physiology
    Language English
    Publishing date 2024-03-19
    Publishing country England
    Document type Journal Article
    ZDB-ID 2041355-5
    ISSN 1471-2474 ; 1471-2474
    ISSN (online) 1471-2474
    ISSN 1471-2474
    DOI 10.1186/s12891-024-07351-y
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article ; Online: Discovering associations between radiological features and COVID-19 patients' deterioration.

    Ahmadinejad, Nasrin / Ayyoubzadeh, Seyed Mohammad / Zeinalkhani, Fahimeh / Delazar, Sina / Javanmard, Zohreh / Ahmadinejad, Zahra / Mohajeri, Amirhassan / Esmaeili, Marzieh

    Health science reports

    2023  Volume 6, Issue 9, Page(s) e1257

    Abstract: Background and aims: Data mining methods are effective and well-known tools for developing predictive models and extracting useful information from various data of patients. The present study aimed to predict the severity of patients with COVID-19 by ... ...

    Abstract Background and aims: Data mining methods are effective and well-known tools for developing predictive models and extracting useful information from various data of patients. The present study aimed to predict the severity of patients with COVID-19 by applying the rule mining method using characteristics of medical images.
    Methods: This retrospective study has analyzed the radiological data from 104 COVID-19 hospitalized patients diagnosed with COVID-19 in a hospital in Iran. A data set containing 75 binary features was generated. Apriori method is utilized for association rule mining on this data set. Only rules with confidence equal to one were generated. The performance of rules is calculated by support, coverage, and lift indexes.
    Results: Ten rules were extracted with only X-ray-related features on cases referred to ICU. The Support and Coverage index of all of these rules was 0.087, and the Lift index of them was 1.58. Thirteen rules were extracted from only CT scan-related features on cases referred to ICU. The CXR_Pleural effusion feature has appeared in all the rules. The CXR_Left upper zone feature appears in 9 rules out of 10. The Support and Coverage index of all rules was 0.15, and the Lift index of all rules was 1.63. the CT_Adjacent pleura thickening feature has appeared in all rules, and the CT_Right middle lobe appeared in 9 rules out of 13.
    Conclusion: This study could reveal the application and efficacy of CXR and CT scan imaging modalities in predicting ICU admission to a major COVID-19 infection via data mining methods. The findings of this study could help data scientists, radiologists, and clinicians in the future development and implementation of these methods in similar conditions and timely and appropriately save patients from adverse disease outcomes.
    Language English
    Publishing date 2023-05-08
    Publishing country United States
    Document type Journal Article
    ISSN 2398-8835
    ISSN (online) 2398-8835
    DOI 10.1002/hsr2.1257
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top