Artikel ; Online: The Geometry of Y-Stent Configurations Used for Wide-Necked Aneurysm Treatment: Analyzing Double-Barrel Stents In Vitro Using Flat-Panel Computed Tomography.
2021 Band 151, Seite(n) e363–e371
Abstract: ... a Y configuration stent. A similar stent configuration, termed kissing/double-barrel (KDB), is used ...
Abstract | Background: Stent-assisted coil embolization of wide-necked bifurcation aneurysms often employs a Y configuration stent. A similar stent configuration, termed kissing/double-barrel (KDB), is used often at the aortoiliac bifurcation. Studies of KDB stents in aortoiliac disease show that rates of thromboembolic complications vary with the cross-sectional geometry of the stent pair, a function of the radial crush resistive force of each stent. We assessed cross-sectional geometry of intracranial stent pairs in an in vitro model of the basilar artery using flat-panel computed tomography. Methods: In a silicone model of a wide-necked basilar tip aneurysm, 6 simulated KDB stent deployment trials were performed using combinations of 5 stents (Enterprise 1, Enterprise 2, Neuroform Atlas, LVIS, LVIS Jr.). Flat-panel computed tomography reconstructions were used to assess cross-sectional stent geometry. Relative conformability, defined by ovalization and D-ratio, radial crush resistive force (predicted vs. actual), and radial mismatch fraction were compared by stent type (braided vs. laser-cut). Results: Several distinct forms of cross-sectional stent geometry were observed. Braided stents had lower ovalization and D-ratio (P = 0.015) than laser-cut stents. The Neuroform Atlas/LVIS combination yielded the lowest radial mismatch fraction (19.7% vs. mean 44.3% ± 0.7%). Braided stents tended to have a deployed stent radius closer to the expected (nominal) diameter (i.e., higher relative crush resistive force) than laser-cut stents (measured vs. nominal diameter discrepancy +38.6% ± 21.1% vs. -10.7% ±16.1%, P = 0.14). Conclusions: In constant anatomy, cross-sectional geometry of the KDB stent configuration will vary depending on the design and structure of the stents employed. |
---|---|
Mesh-Begriff(e) | Embolization, Therapeutic/methods ; Endovascular Procedures/methods ; Humans ; Intracranial Aneurysm/diagnostic imaging ; Intracranial Aneurysm/surgery ; Models, Neurological ; Stents ; Tomography, X-Ray Computed |
Sprache | Englisch |
Erscheinungsdatum | 2021-04-19 |
Erscheinungsland | United States |
Dokumenttyp | Journal Article |
ZDB-ID | 2534351-8 |
ISSN | 1878-8769 ; 1878-8750 |
ISSN (online) | 1878-8769 |
ISSN | 1878-8750 |
DOI | 10.1016/j.wneu.2021.04.042 |
Datenquelle | MEDical Literature Analysis and Retrieval System OnLINE |
Volltext online
Zusatzmaterialien
Kategorien
Verfügbar in ZB MED Köln/Königswinter
Zs.A 1159: Hefte anzeigen | Standort: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular Jg. 1995 - 2021: Lesesall (1.OG) ab Jg. 2022: Lesesaal (EG) |
Über subito bestellen
Dieser Service ist kostenpflichtig (siehe Lieferbedingungen von subito). Bestellungen, die einen Artikel nebst Supplementary Material umfassen, werden grundsätzlich wie mehrfache Bestellungen bearbeitet. Gebühren fallen in diesen Fällen für jede einzelne Bestellung an.