Artikel ; Online: The evaluation of a non-invasive respiratory monitor in ards patients in supine and prone position.
Journal of clinical monitoring and computing
2024 Band 38, Heft 3, Seite(n) 671–677
Abstract: Purpose: The Prone positioning in addition to non invasive respiratory support is commonly used in patients with acute respiratory failure. The aim of this study was to assess the accuracy of an impedance-based non-invasive respiratory volume monitor ( ... ...
Abstract | Purpose: The Prone positioning in addition to non invasive respiratory support is commonly used in patients with acute respiratory failure. The aim of this study was to assess the accuracy of an impedance-based non-invasive respiratory volume monitor (RVM) in supine and in prone position. Methods: In sedated, paralyzed and mechanically ventilated patients in volume-controlled mode with acute respiratory distress syndrome scheduled for prone positioning it was measured and compared non-invasively tidal volume and respiratory rate provided by the RVM in supine and, subsequently, in prone position, by maintaining unchanged the ventilatory setting. Results: Forty patients were enrolled. No significant difference was found between measurements in supine and in prone position either for tidal volume (p = 0.795; p = 0.302) nor for respiratory rate (p = 0.181; p = 0.604). Comparing supine vs. prone position, the bias and limits of agreements for respiratory rate were 0.12 bpm (-1.4 to 1.6) and 20 mL (-80 to 120) for tidal volume. Conclusions: The RVM is accurate in assessing tidal volume and respiratory rate in prone compared to supine position. Therefore, the RVM could be applied in non-intubated patients with acute respiratory failure receiving prone positioning to monitor respiratory function. |
|||||
---|---|---|---|---|---|---|
Mesh-Begriff(e) | Humans ; Prone Position ; Respiratory Distress Syndrome/physiopathology ; Respiratory Distress Syndrome/therapy ; Supine Position ; Male ; Female ; Tidal Volume ; Middle Aged ; Monitoring, Physiologic/methods ; Monitoring, Physiologic/instrumentation ; Aged ; Respiration, Artificial/methods ; Respiratory Rate ; Adult ; Patient Positioning/methods ; Reproducibility of Results ; Electric Impedance | |||||
Sprache | Englisch | |||||
Erscheinungsdatum | 2024-03-26 | |||||
Erscheinungsland | Netherlands | |||||
Dokumenttyp | Journal Article | |||||
ZDB-ID | 1418733-4 | |||||
ISSN | 1573-2614 ; 1387-1307 ; 0748-1977 | |||||
ISSN (online) | 1573-2614 | |||||
ISSN | 1387-1307 ; 0748-1977 | |||||
DOI | 10.1007/s10877-024-01147-0 | |||||
Signatur |
|
|||||
Datenquelle | MEDical Literature Analysis and Retrieval System OnLINE |
Volltext online
Zusatzmaterialien
Kategorien
Verfügbar in ZB MED Köln/Königswinter
Zs.A 2054: Hefte anzeigen | Standort: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular Jg. 1995 - 2021: Lesesall (1.OG) ab Jg. 2022: Lesesaal (EG) |
Über subito bestellen
Dieser Service ist kostenpflichtig (siehe Lieferbedingungen von subito). Bestellungen, die einen Artikel nebst Supplementary Material umfassen, werden grundsätzlich wie mehrfache Bestellungen bearbeitet. Gebühren fallen in diesen Fällen für jede einzelne Bestellung an.