LIVIVO - Das Suchportal für Lebenswissenschaften

switch to English language
Erweiterte Suche

Suchergebnis

Treffer 1 - 5 von insgesamt 5

Suchoptionen

  1. Artikel ; Online: Comparison of Treatment Outcomes Between Thoracoscopic Surgery and Stereotactic Body Radiotherapy for Early-Stage Non-Small Cell Lung Cancer.

    Tian, Qin / Zhao, Xinxin / Zhang, Cong / Tian, Nannan / Bian, Hongchun

    Technology in cancer research & treatment

    2024  Band 23, Seite(n) 15330338231219369

    Abstract: Objective: ...

    Abstract Objective:
    Mesh-Begriff(e) Humans ; Carcinoma, Non-Small-Cell Lung/radiotherapy ; Carcinoma, Non-Small-Cell Lung/surgery ; Lung Neoplasms/radiotherapy ; Lung Neoplasms/surgery ; Radiosurgery/adverse effects ; Neoplasm Recurrence, Local/pathology ; Retrospective Studies ; Kaplan-Meier Estimate ; Small Cell Lung Carcinoma/pathology ; Treatment Outcome ; Thoracoscopy ; Disease Progression ; Neoplasm Staging
    Sprache Englisch
    Erscheinungsdatum 2024-02-19
    Erscheinungsland United States
    Dokumenttyp Journal Article
    ZDB-ID 2146365-7
    ISSN 1533-0338 ; 1533-0346
    ISSN (online) 1533-0338
    ISSN 1533-0346
    DOI 10.1177/15330338231219369
    Datenquelle MEDical Literature Analysis and Retrieval System OnLINE

    Zusatzmaterialien

    Kategorien

  2. Artikel ; Online: Clinical application of bronchial high-frequency ventilation in 2-port thoracoscopic segmentectomy.

    Li, Bing / Zou, Zhiqiang / Zhang, Wei / Bian, Hongchun / Li, Yucai

    Medicine

    2022  Band 101, Heft 43, Seite(n) e31611

    Abstract: To evaluate the safety and clinical application of a computer-aided surgery system (CAS) combined with high-frequency bronchial ventilation in 2-port thoracoscopic anatomical segmentectomy. A total of 301 patients who underwent 2-port thoracoscopic ... ...

    Abstract To evaluate the safety and clinical application of a computer-aided surgery system (CAS) combined with high-frequency bronchial ventilation in 2-port thoracoscopic anatomical segmentectomy. A total of 301 patients who underwent 2-port thoracoscopic segmentectomy between January 1, 2019 and March 1, 2022 in the 960th Hospital of the People's Liberation Army and the Department of Thoracic Surgery of Zibo Municipal Hospital were retrospectively analyzed. The experimental and control groups were created according to the different methods of appearing the intersegmental plane of the lung. The experimental group comprised 152 patients who underwent CAS reconstruction combined with high-frequency ventilation, and the control group comprised 149 patients who underwent CAS reconstruction combined with expansion collapse. The characteristics of the patients, including age, sex, smoking history, forced expiratory volume in 1 second/forced vital capacity, Maximal ventilation, diameter of pulmonary nodules, intraoperative blood loss, postoperative drainage volume, drainage tube removal time, length of hospital stay after extubation, postoperative complication rate, operation time and appearance time of the intersegmental plane, were compared between the 2 groups. All patients completed the operation between high-frequency bronchial ventilation and expansion collapse group. There was no significant difference in Forced expiratory volume in 1 second/Forced vital capacity [(101.05 ± 11.86) vs (101.86 ± 11.61)], maximum expiratory volume [(86.36 ± 17.59 L) vs (85.28 ± 17.68 L)], the diameter of lung nodules [(13.61 ± 3.51 cm) vs (13.21 ± 3.41 cm)], intraoperative blood loss [(47.50 ± 45.90 mL) vs (48.49 ± 34.65 mL)], postoperative drainage volume [(425.16 ± 221.61 mL) vs (444.70 ± 243.72 mL)], drainage tube removal time [(3.88 ± 1.85 days) vs (3.43 ± 1.81 days)], or postoperative hospital stay [(6.07 ± 2.14 days) vs (5.82 ± 1.88 days) between the experimental group and the control group (P > .05)]. There were significant differences in operation time [(95.05 ± 26.85 min) vs (117.85 ± 31.70 min), P = .017] and intersegmental plane appearance time [(2.37 ± 1.03 min) vs (14.20 ± 3.23 min), P < .001]. High-frequency bronchial ventilation is safe and feasible when used in quickly and accurately identifying the intersegmental plane and is worthy of clinical application in 2-port thoracoscopic segmentectomy.
    Mesh-Begriff(e) Humans ; Pneumonectomy/methods ; Thoracic Surgery, Video-Assisted/methods ; Lung Neoplasms/surgery ; Retrospective Studies ; Blood Loss, Surgical ; High-Frequency Ventilation
    Sprache Englisch
    Erscheinungsdatum 2022-11-01
    Erscheinungsland United States
    Dokumenttyp Journal Article
    ZDB-ID 80184-7
    ISSN 1536-5964 ; 0025-7974
    ISSN (online) 1536-5964
    ISSN 0025-7974
    DOI 10.1097/MD.0000000000031611
    Datenquelle MEDical Literature Analysis and Retrieval System OnLINE

    Zusatzmaterialien

    Kategorien

  3. Artikel: Rapid and visual detection of Mycoplasma synoviae by recombinase-aided amplification assay combined with a lateral flow dipstick

    Xia, Wenlong / Chen, Ke / Liu, Wensong / Yin, Yan / Yao, Qian / Ban, Yu / Pu, Yiwen / Zhan, Xingmin / Bian, Hongchun / Yu, Shupei / Han, Kunpeng / Yang, Ling / Wang, Huanli / Fan, Zhongjun

    Poultry science. 2022 Mar. 08,

    2022  

    Abstract: Mycoplasma synoviae (MS) is an important avian pathogen that has brought substantial economic losses to the global poultry industry. Fast and accurate diagnosis is one of the critical factors for the control of MS infection. This study established a ... ...

    Abstract Mycoplasma synoviae (MS) is an important avian pathogen that has brought substantial economic losses to the global poultry industry. Fast and accurate diagnosis is one of the critical factors for the control of MS infection. This study established a simple, rapid and visual detection method for MS using a recombinase-aided amplification (RAA) combined with a lateral flow dipstick (LFD). The reaction temperature and time of the RAA-LFD assay were optimized after selecting the primers and probe, and the specificity and sensitivity rates were analyzed. The results showed that RAA could amplify the target gene in 20 min at a constant temperature of 38°C, and the amplification products could be visualized by LFD within 5 min. There was no cross-reaction with Mycoplasma gallisepticum (MG), Pasteurella multocida (P.multocida), Escherichia coli (E.coli), Newcastle disease virus (NDV), infectious bursal disease virus (IBDV), infectious bronchitis virus (IBV), and avian reovirus (ARV). Furthermore, the RAA-LFD assay exhibited high sensitivity with a detection limit of 10 copies/μL. A total of 128 clinical samples with suspected infection of MS were tested by RAA-LFD, PCR and real-time fluorescence quantitative PCR (RFQ-PCR). The coincidence rate of the detection results was 95.3% between RAA-LFD and PCR, and 98.4% between RAA-LFD and RFQ-PCR. These results suggested that the RAA-LFD method established in the present study was easy to use and was associated with stong specificity and high sensitivity. This method was very suitable for the rapid detection of MS in clinical practice.
    Schlagwörter Avian orthoavulavirus 1 ; Avian orthoreovirus ; Escherichia coli ; Infectious bronchitis virus ; Infectious bursal disease virus ; Mycoplasma gallisepticum ; Mycoplasma synoviae ; Pasteurella multocida ; birds ; cross reaction ; detection limit ; fluorescence ; genes ; pathogens ; poultry industry ; poultry science ; quantitative polymerase chain reaction ; rapid methods ; temperature
    Sprache Englisch
    Erscheinungsverlauf 2022-0308
    Erscheinungsort Elsevier Inc.
    Dokumenttyp Artikel
    Anmerkung Pre-press version
    ZDB-ID 242586-5
    ISSN 1525-3171 ; 0032-5791
    ISSN (online) 1525-3171
    ISSN 0032-5791
    DOI 10.1016/j.psj.2022.101860
    Datenquelle NAL Katalog (AGRICOLA)

    Zusatzmaterialien

    Kategorien

  4. Artikel ; Online: Rapid and visual detection of Mycoplasma synoviae by recombinase-aided amplification assay combined with a lateral flow dipstick.

    Xia, Wenlong / Chen, Ke / Liu, Wensong / Yin, Yan / Yao, Qian / Ban, Yu / Pu, Yiwen / Zhan, Xingmin / Bian, Hongchun / Yu, Shupei / Han, Kunpeng / Yang, Ling / Wang, Huanli / Fan, Zhongjun

    Poultry science

    2022  Band 101, Heft 7, Seite(n) 101860

    Abstract: Mycoplasma synoviae (MS) is an important avian pathogen that has brought substantial economic losses to the global poultry industry. Fast and accurate diagnosis is one of the critical factors for the control of MS infection. This study established a ... ...

    Abstract Mycoplasma synoviae (MS) is an important avian pathogen that has brought substantial economic losses to the global poultry industry. Fast and accurate diagnosis is one of the critical factors for the control of MS infection. This study established a simple, rapid and visual detection method for MS using a recombinase-aided amplification (RAA) combined with a lateral flow dipstick (LFD). The reaction temperature and time of the RAA-LFD assay were optimized after selecting the primers and probe, and the specificity and sensitivity rates were analyzed. The results showed that RAA could amplify the target gene in 20 min at a constant temperature of 38°C, and the amplification products could be visualized by LFD within 5 min. There was no cross-reaction with Mycoplasma gallisepticum (MG), Pasteurella multocida (P. multocida), Escherichia coli (E. coli), Newcastle disease virus (NDV), infectious bursal disease virus (IBDV), infectious bronchitis virus (IBV), and avian reovirus (ARV). Furthermore, the RAA-LFD assay exhibited high sensitivity with a detection limit of 10 copies/μL. A total of 128 clinical samples with suspected infection of MS were tested by RAA-LFD, PCR, and real-time fluorescence quantitative PCR (RFQ-PCR). The coincidence rate of the detection results was 95.3% between RAA-LFD and PCR, and 98.4% between RAA-LFD and RFQ-PCR. These results suggested that the RAA-LFD method established in the present study was easy to use and was associated with strong specificity and high sensitivity. This method was very suitable for the rapid detection of MS in clinical practice.
    Mesh-Begriff(e) Animals ; Chickens ; Escherichia coli ; Mycoplasma synoviae/genetics ; Nucleic Acid Amplification Techniques/methods ; Nucleic Acid Amplification Techniques/veterinary ; Recombinases ; Sensitivity and Specificity
    Chemische Substanzen Recombinases
    Sprache Englisch
    Erscheinungsdatum 2022-03-15
    Erscheinungsland England
    Dokumenttyp Journal Article
    ZDB-ID 242586-5
    ISSN 1525-3171 ; 0032-5791
    ISSN (online) 1525-3171
    ISSN 0032-5791
    DOI 10.1016/j.psj.2022.101860
    Datenquelle MEDical Literature Analysis and Retrieval System OnLINE

    Zusatzmaterialien

    Kategorien

  5. Artikel ; Online: Effects of dezocine on neuronal apoptosis induced by cerebral ischemia/reperfusion.

    Gao, Chengjie / Gao, Shengrun / Zhao, Xiaohong / Wang, Fei / Wang, Huixia / Bian, Hongchun / Qiang, Song / Wang, Xiangyang

    Minerva medica

    2020  Band 114, Heft 1, Seite(n) 130–132

    Mesh-Begriff(e) Humans ; Brain Ischemia ; Cerebral Infarction
    Chemische Substanzen dezocine (VHX8K5SV4X)
    Sprache Englisch
    Erscheinungsdatum 2020-12-02
    Erscheinungsland Italy
    Dokumenttyp Journal Article
    ZDB-ID 123586-2
    ISSN 1827-1669 ; 0026-4806
    ISSN (online) 1827-1669
    ISSN 0026-4806
    DOI 10.23736/S0026-4806.20.07162-1
    Datenquelle MEDical Literature Analysis and Retrieval System OnLINE

    Zusatzmaterialien

    Kategorien

Zum Seitenanfang