LIVIVO - Das Suchportal für Lebenswissenschaften

switch to English language
Erweiterte Suche

Suchergebnis

Treffer 1 - 1 von insgesamt 1

Suchoptionen

Artikel ; Online: Enhancing the repeatability and sensitivity of low-cost PCB, pH-sensitive field-effect transistors.

Ashton, Rhys / Silver, Callum D / Bird, Toby W / Coulson, Ben / Pratt, Andrew / Johnson, Steven

Biosensors & bioelectronics

2023  Band 227, Seite(n) 115150

Abstract: Discrete, extended gate pH-sensitive field-effect transistors (dEGFETs) fabricated on printed circuit boards (PCBs) are a low-cost, simple to manufacture analytical technology that can be applied to a wide range of applications. Electrodeposited iridium ... ...

Abstract Discrete, extended gate pH-sensitive field-effect transistors (dEGFETs) fabricated on printed circuit boards (PCBs) are a low-cost, simple to manufacture analytical technology that can be applied to a wide range of applications. Electrodeposited iridium oxide (IrOx) films have emerged as promising pH-sensitive layers owing to their theoretically high pH sensitivity and facile deposition, but typically exhibit low pH sensitivity or lack reproducibility. Moreover, to date, a combined IrOx and dEGFET PCB system has not yet been realised. In this study, we demonstrate a dEGFET pH sensor based on an extended gate manufactured on PCB that is rendered pH sensitive through an electrodeposited IrOx film, which can reliably and repeatably display beyond-Nernstian pH response. Using a combination of complementary surface analysis techniques, we show that the high pH sensitivity and repeatability of the dEGFETs are dependent on both the chemical composition and critically the uniformity of the IrOx film. The IrOx film uniformity can be enhanced through electrochemical polishing of the extended gate electrode prior to electrodeposition, leading to dEGFETs that exhibit a median pH sensitivity of 70.7 ± 5 mV/pH (n = 56) compared to only 31.3 ± 14 mV/pH (n = 31) for IrOx electrodeposited on non-polished PCB electrodes. Finally, we demonstrate the applicability of these devices by demonstrating the detection and quantification of ampicillin due to β-Lactamase enzyme activity, thus laying the foundation for cheap and ubiquitous sensors which can be applied to a range of global challenges across healthcare and environmental monitoring.
Mesh-Begriff(e) Reproducibility of Results ; Biosensing Techniques/methods ; Electrodes ; Hydrogen-Ion Concentration
Sprache Englisch
Erscheinungsdatum 2023-02-16
Erscheinungsland England
Dokumenttyp Journal Article
ZDB-ID 1011023-9
ISSN 1873-4235 ; 0956-5663
ISSN (online) 1873-4235
ISSN 0956-5663
DOI 10.1016/j.bios.2023.115150
Signatur
Zs.A 2275: Hefte anzeigen Standort:
Je nach Verfügbarkeit (siehe Angabe bei Bestand)
bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular
Jg. 1995 - 2021: Lesesall (2.OG)
ab Jg. 2022: Lesesaal (EG)
Datenquelle MEDical Literature Analysis and Retrieval System OnLINE

Zusatzmaterialien

Kategorien

Zum Seitenanfang