Artikel ; Online: Accuracy of skinfold and bioelectrical impedance assessments of body fat percentage in ambulatory individuals with cerebral palsy.
Developmental medicine and child neurology
2014 Band 56, Heft 5, Seite(n) 475–481
Abstract: Aim: This study assessed the accuracy of measurements of body fat percentage in ambulatory individuals with cerebral palsy (CP) from bioelectrical impedance analysis (BIA) and skinfold equations.: Method: One hundred and twenty-eight individuals (65 ... ...
Abstract | Aim: This study assessed the accuracy of measurements of body fat percentage in ambulatory individuals with cerebral palsy (CP) from bioelectrical impedance analysis (BIA) and skinfold equations. Method: One hundred and twenty-eight individuals (65 males, 63 females; mean age 12y, SD 3, range 6-18y) with CP (Gross Motor Function Classification System [GMFCS] levels I (n=6), II (n=46), and III (n=19) participated. Body fat percentage was estimated from (1) BIA using standing height and estimated heights (knee height and tibial length) and (2) triceps and subscapular skinfolds using standard and CP-specific equations. All estimates of body fat percentage were compared with body fat percentage from dual-energy X-ray absorptiometry (DXA) scans. Differences between DXA, BIA, and skinfold body fat percentage were analyzed by comparing mean differences. Agreement was assessed by Bland-Altman plots and concordance correlation coefficients (CCC). Results: BMI was moderately correlated with DXA (Pearson's r=0.53). BIA body fat percentage was significantly different from DXA when using estimated heights (95% confidence intervals [CIs] do not contain 0) but not standing height (95% CI -1.9 to 0.4). CCCs for all BIA comparisons indicated good to excellent agreement (0.75-0.82) with DXA. Body fat percentage from skinfold measurements and CP-specific equations was not significantly different from DXA (mean 0.8%; SD 5.3%; 95% CI -0.2 to 1.7) and demonstrated strong agreement with DXA (CCC 0.86). Interpretation: Accurate measures of body fat percentage can be obtained using BIA and two skinfold measurements (CP-specific equations) in ambulatory individuals with CP. These findings should encourage assessments of body fat in clinical and research practices. |
|||||
---|---|---|---|---|---|---|
Mesh-Begriff(e) | Absorptiometry, Photon ; Adipose Tissue/physiopathology ; Adolescent ; Anthropometry ; Body Mass Index ; Cerebral Palsy/pathology ; Cerebral Palsy/physiopathology ; Child ; Electric Impedance ; Female ; Humans ; Male ; Skinfold Thickness ; Statistics as Topic | |||||
Sprache | Englisch | |||||
Erscheinungsdatum | 2014-05 | |||||
Erscheinungsland | England | |||||
Dokumenttyp | Journal Article ; Research Support, Non-U.S. Gov't | |||||
ZDB-ID | 80369-8 | |||||
ISSN | 1469-8749 ; 0012-1622 | |||||
ISSN (online) | 1469-8749 | |||||
ISSN | 0012-1622 | |||||
DOI | 10.1111/dmcn.12342 | |||||
Signatur |
|
|||||
Datenquelle | MEDical Literature Analysis and Retrieval System OnLINE |
Volltext online
Zusatzmaterialien
Kategorien
Verfügbar in ZB MED Köln/Königswinter
Zs.B 5: Hefte anzeigen | Standort: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 2021: Bestellungen von Artikeln über das Online-Bestellformular ab Jg. 2022: Lesesaal (EG) |
Über subito bestellen
Dieser Service ist kostenpflichtig (siehe Lieferbedingungen von subito). Bestellungen, die einen Artikel nebst Supplementary Material umfassen, werden grundsätzlich wie mehrfache Bestellungen bearbeitet. Gebühren fallen in diesen Fällen für jede einzelne Bestellung an.