Artikel ; Online: Development of a Near Infrared Spectroscopy method for the in-line quantitative bilastine drug determination during pharmaceutical powders blending.
Journal of pharmaceutical and biomedical analysis
2021 Band 204, Seite(n) 114277
Abstract: The Food and Drug Administration (FDA)'s guidelines and the Process Analytical Technology (PAT) approach conceptualize the idea of real time monitoring of a process, with the primary objective of improvement of quality and also of time and resources ... ...
Abstract | The Food and Drug Administration (FDA)'s guidelines and the Process Analytical Technology (PAT) approach conceptualize the idea of real time monitoring of a process, with the primary objective of improvement of quality and also of time and resources saving. New instruments are needed to perform an efficient PAT process control and Near Infrared Spectroscopy (NIRS), thanks to its rapid and drastic development of last years, could be a very good choice, in virtue of its high versatility, speed of analysis, non-destructiveness and absence of sample chemical treatment. This work was aimed to develop a NIR analytical method for bilastine assay in powder mixtures for direct compression. In particular, the use of NIR instrumentation should allow to control the bilastine concentration and the whole blending process, assuring the achievement of a homogeneous blend. The commercial tablet formulation of bilastine was particularly suitable for this purpose, due to its simple composition (four excipients) and direct compression manufacturing process. Calibration and validation set were prepared according to a Placket-Burman experimental design and acquired with a miniaturized NIR in-line instrument (MicroNIR by Viavi Solution Inc.). Chemometric was applied to optimize information extraction from spectra, by subjecting them to a Standard Normal Variate (SNV) and a Savitzky-Golay second derivative pre-treatment. This spectra pre-treatment, combined with the most suitable wavelength interval (resulted between 1087 and 1217 nm), enabled to obtain a Partial Least Square (PLS) model with a good predictive ability. The selected model, tried on laboratory and production batches, provided in both cases good assay predictions. Results were confirmed by traditional HPLC (High Performance Liquid Chromatography) API (Active Pharmaceutical Ingredient) content uniformity test on the final product. |
---|---|
Mesh-Begriff(e) | Benzimidazoles ; Calibration ; Drug Compounding ; Least-Squares Analysis ; Piperidines ; Powders ; Research Design ; Spectroscopy, Near-Infrared ; Tablets ; Technology, Pharmaceutical |
Chemische Substanzen | Benzimidazoles ; Piperidines ; Powders ; Tablets ; bilastine (PA1123N395) |
Sprache | Englisch |
Erscheinungsdatum | 2021-07-22 |
Erscheinungsland | England |
Dokumenttyp | Journal Article |
ZDB-ID | 604917-5 |
ISSN | 1873-264X ; 0731-7085 |
ISSN (online) | 1873-264X |
ISSN | 0731-7085 |
DOI | 10.1016/j.jpba.2021.114277 |
Datenquelle | MEDical Literature Analysis and Retrieval System OnLINE |
Volltext online
Zusatzmaterialien
Kategorien
Verfügbar in ZB MED Köln/Königswinter
Zs.A 1850: Hefte anzeigen | Standort: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular Jg. 1995 - 2021: Lesesall (1.OG) ab Jg. 2022: Lesesaal (EG) |
Über subito bestellen
Dieser Service ist kostenpflichtig (siehe Lieferbedingungen von subito). Bestellungen, die einen Artikel nebst Supplementary Material umfassen, werden grundsätzlich wie mehrfache Bestellungen bearbeitet. Gebühren fallen in diesen Fällen für jede einzelne Bestellung an.