LIVIVO - Das Suchportal für Lebenswissenschaften

switch to English language
Erweiterte Suche

Suchergebnis

Treffer 1 - 2 von insgesamt 2

Suchoptionen

  1. Artikel ; Online: A case report

    Do Duc Thuan, PhD / Nguyen Thi Nguyet, MD / Le Duy Chi, MD / Dao Van Nhat, MS / Dinh Viet Hung, PhD / Nguyen Khanh, MS / Pham Ngoc Thao, PhD / Nguyen Thanh Xuan, PhD

    Radiology Case Reports, Vol 18, Iss 3, Pp 862-

    Ruptured aneurysm with a wide neck treated by flow diverter stent and coil embolization

    2023  Band 868

    Abstract: Diagnosis and endovascular treatment for ruptured wide neck aneurysms are challenges in clinics, particularly in developing countries. In the present study, we described a clinical case with a ruptured wide neck aneurysm in Vietnam treated by flow ... ...

    Abstract Diagnosis and endovascular treatment for ruptured wide neck aneurysms are challenges in clinics, particularly in developing countries. In the present study, we described a clinical case with a ruptured wide neck aneurysm in Vietnam treated by flow diverter stent and coil embolization. A 77-year-old- female patient had a right droopy eyelid for 2 months. The patient was admitted to hospital on the second day after being presented with a sudden-severe headache. Cerebral computed tomography (CT) and magnetic resonance imaging (MRI) were taken on the second day and fifth day after the onset of the headache. The results showed an aneurysm in the right internal carotid artery but no potential subarachnoid hemorrhage (SAH) was displayed. An uncoagulated blood was found in cerebrospinal fluid indicated by a lumbar puncture test. Digital subtraction angiography provided images with one wide-neck right internal carotid aneurysm. The patient was treated by flow diverter stent and coil embolization and the dual antiplatelet therapy with ticagrelor and aspirin at home. After 45 days, the patient did not face with any complication, no neurological symptoms, and the aneurysm was partially thrombosed indicated by MRI images. These results suggested that a lumbar puncture should be analyzed on the patient with brain aneurysm appeared a sudden severe headache and even no potential SAH on brain MRI or CT was found. The combination of flow diverter stent and coil embolization to treat cases with ruptured wide necked aneurysms should be considered in the future.
    Schlagwörter Wide neck aneurysm ; Flow diverter stent ; Ruptured aneurysm ; Flow diverter stent and coil embolization ; Medical physics. Medical radiology. Nuclear medicine ; R895-920
    Thema/Rubrik (Code) 616 ; 610
    Sprache Englisch
    Erscheinungsdatum 2023-03-01T00:00:00Z
    Verlag Elsevier
    Dokumenttyp Artikel ; Online
    Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

    Zusatzmaterialien

    Kategorien

  2. Artikel ; Online: Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans in blood samples from historically herbicide-sprayed areas and rural and industrialized unsprayed areas in Vietnam.

    Vu, Tung Son / Nishijo, Muneko / Nishino, Yoshikazu / Vu, Chien Thang / Nguyen, Van Chuyen / Pham, The Tai / Do, Ngoc Anh / Vu, Ngoc Hoan / Le, Duy Chi / Dao, Van Nhat / Dinh, Viet Hung / Pham, Ngoc Thao / Do, Duc Thuan

    Chemosphere

    2023  Band 326, Seite(n) 138331

    Abstract: We investigated dioxin concentrations in the blood of residents living in areas with different sources of dioxin pollution in Vietnam. A total of 823 individual blood samples were collected in 2014-2015 from residents of 16 provinces in Vietnam who were ... ...

    Abstract We investigated dioxin concentrations in the blood of residents living in areas with different sources of dioxin pollution in Vietnam. A total of 823 individual blood samples were collected in 2014-2015 from residents of 16 provinces in Vietnam who were born between 1972 and 1976, and who lived in rural unsprayed areas (the control area), industrialized unsprayed areas (the industrialized area), and areas in which herbicides were sprayed during the Vietnam War (the sprayed area). After blood collection, pooled samples were obtained by combining 10-25 individual samples by age and sex for each area. A total of 6, 10, and 26 pooled blood samples were obtained for the control area, industrialized area, and sprayed area, respectively. The concentrations of 17 polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans were quantified in each pooled blood sample. The concentrations of TCDD, 1,2,3,7,8,9-HxCDD, 1,2,3,7,8-PeCDF, and OCDF were significantly higher in the sprayed area than in the unsprayed area, which comprised the control and industrialized areas. The toxic equivalents of PCDDs, TCDD, 1,2,3,7,8-PeCDF, and 1,2,3,6,7,8-HxCDF were significantly higher in the sprayed area than in the control area. No significant difference in dioxin concentration was found between the sprayed and industrialized areas after adjusting for sex. The 1,2,3,6,7,8-HxCDF concentration was significantly higher in the industrialized area than in the control area. The findings indicate that there are different dioxin congener blood profiles in residents of industrialized areas and areas in which herbicides were historically sprayed during the Vietnam War.
    Mesh-Begriff(e) Herbicides ; Dioxins ; Dibenzofurans, Polychlorinated ; Vietnam ; Polychlorinated Dibenzodioxins ; Polychlorinated Biphenyls
    Chemische Substanzen Herbicides ; Dioxins ; Dibenzofurans, Polychlorinated ; Polychlorinated Dibenzodioxins ; Polychlorinated Biphenyls (DFC2HB4I0K)
    Sprache Englisch
    Erscheinungsdatum 2023-03-21
    Erscheinungsland England
    Dokumenttyp Journal Article
    ZDB-ID 120089-6
    ISSN 1879-1298 ; 0045-6535 ; 0366-7111
    ISSN (online) 1879-1298
    ISSN 0045-6535 ; 0366-7111
    DOI 10.1016/j.chemosphere.2023.138331
    Datenquelle MEDical Literature Analysis and Retrieval System OnLINE

    Zusatzmaterialien

    Kategorien

Zum Seitenanfang