Artikel ; Online: Notre faux-ami le rayon X - Risques, évaluation, protection, amélioration des pratiques - État des lieux par le registre France- PCI.
Annales de cardiologie et d'angeiologie
2021 Band 70, Heft 6, Seite(n) 416–424
Abstract: Although indispensable, radiation exposure during cardiac catheterization procedures can cause specific radiation-induced diseases. These affect the patient but also the interventional cardiologist. Exposure to high or repeated radiation doses causes ... ...
Titelübersetzung | X-Ray, false friend of the interventional cardiologist - Risks, evaluation, quality improvement - Status report from France-PCI registry. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Abstract | Although indispensable, radiation exposure during cardiac catheterization procedures can cause specific radiation-induced diseases. These affect the patient but also the interventional cardiologist. Exposure to high or repeated radiation doses causes deterministic effects. Moreover, even low-dose exposure, especially when repeated, produces a risk of stochastic effets. In that respect, it is crucial to improve the radiation safety of cardiac angiography and interventions, to promote radiation protection and to maintain this exposure « As Low As Reasonably Achievable ». Thus, there is a necessity to spread knowledge about safety standards and recommandations to reduces the dose among interventionalists. Data collection and comparaison of practices are precious to this quality improvement process. For the year 2020, France-PCI registry had collected dosimetric datas related to 55 783 coronary angiographic and interventional procedures from 30 centers in France. Mean fluoroscopy time was 4,4 minutes for diagnostic procedures. Mean PDS was 1 767cGy.Cm2 and mean Air Kerma de 257Gy. Coronary percutaneous angioplasty procedures were related to approximately two to three times higher mean exposures. Mean exposure related to chronic coronary total occlusion treatment procedures was also two times higher than exposure related to non-CTO interventions. These data also highlighted wide disparities between centers. |
||||||||||
Mesh-Begriff(e) | Cardiologists ; Coronary Angiography/adverse effects ; Humans ; Percutaneous Coronary Intervention/adverse effects ; Quality Improvement ; Radiation Dosage ; Radiography, Interventional/adverse effects ; Registries ; X-Rays | ||||||||||
Sprache | Französisch | ||||||||||
Erscheinungsdatum | 2021-10-31 | ||||||||||
Erscheinungsland | France | ||||||||||
Dokumenttyp | Journal Article | ||||||||||
ZDB-ID | 418425-7 | ||||||||||
ISSN | 1768-3181 ; 0003-3928 | ||||||||||
ISSN (online) | 1768-3181 | ||||||||||
ISSN | 0003-3928 | ||||||||||
DOI | 10.1016/j.ancard.2021.10.003 | ||||||||||
Signatur |
|
||||||||||
Datenquelle | MEDical Literature Analysis and Retrieval System OnLINE |
Volltext online
Zusatzmaterialien
Kategorien
Verfügbar in ZB MED Köln/Königswinter
Zs.B 47: Hefte anzeigen | Standort: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 2021: Bestellungen von Artikeln über das Online-Bestellformular ab Jg. 2022: Lesesaal (EG) |
|||
Zs.MO 216: Hefte anzeigen |
Über subito bestellen
Dieser Service ist kostenpflichtig (siehe Lieferbedingungen von subito). Bestellungen, die einen Artikel nebst Supplementary Material umfassen, werden grundsätzlich wie mehrfache Bestellungen bearbeitet. Gebühren fallen in diesen Fällen für jede einzelne Bestellung an.