Artikel ; Online: An Alternative Approach for Treating a Type Ia Endoleak after Conventional EVAR Using the Nellix Endovascular Aneurysm Sealing.
2018 Band 49, Seite(n) 316.e5–316.e10
Abstract: Background: To report the use of a Nellix endovascular aneurysm sealing (EVAS) device, to successfully treat a type Ia endoleak (EL) after an endovascular aortic repair (EVAR).: Case report: A 70-year-old man was diagnosed with a 90-mm aortic ... ...
Abstract | Background: To report the use of a Nellix endovascular aneurysm sealing (EVAS) device, to successfully treat a type Ia endoleak (EL) after an endovascular aortic repair (EVAR). Case report: A 70-year-old man was diagnosed with a 90-mm aortic aneurysm, suspicious for being inflammatory. It was initially treated successfully, with a Medtronic Endurant (Medtronic, Minneapolis, MN, USA). Five years after the index endovascular repair, an asymptomatic type Ia EL was detected on duplex ultrasound and computed tomographic angiogram. Other endovascular solutions in the form of proximal cuff, chimney was considered difficult to execute due to challenges in planning, manipulation, and renal cannulation caused by the short proximal sealing zone above the existing stent graft and the constraints of the previous endograft. Thus, a relining of the previous endoprothesis was performed using the Nellix system (Endologix, Inc., Irvine, CA, USA). One-year follow-up imaging demonstrated successful resolution of the EL and persistent sealing of the Nellix device. Conclusions: Nellix EVAS system can be an alternative and safe option for relining a stent graft with a type Ia EL. Nellix platform can be added to the clinician's armamentarium for treating type Ia EL after conventional EVAR of infrarenal abdominal aortic aneurysm (AAA). |
---|---|
Mesh-Begriff(e) | Aged ; Aortic Aneurysm, Abdominal/diagnostic imaging ; Aortic Aneurysm, Abdominal/surgery ; Aortography/methods ; Blood Vessel Prosthesis ; Blood Vessel Prosthesis Implantation/adverse effects ; Blood Vessel Prosthesis Implantation/instrumentation ; Computed Tomography Angiography ; Endoleak/diagnostic imaging ; Endoleak/etiology ; Endoleak/surgery ; Endovascular Procedures/adverse effects ; Endovascular Procedures/instrumentation ; Humans ; Male ; Prosthesis Design ; Stents ; Treatment Outcome ; Ultrasonography, Doppler, Duplex |
Sprache | Englisch |
Erscheinungsdatum | 2018-03-01 |
Erscheinungsland | Netherlands |
Dokumenttyp | Case Reports ; Journal Article |
ZDB-ID | 1027366-9 |
ISSN | 1615-5947 ; 0890-5096 |
ISSN (online) | 1615-5947 |
ISSN | 0890-5096 |
DOI | 10.1016/j.avsg.2017.12.020 |
Datenquelle | MEDical Literature Analysis and Retrieval System OnLINE |
Zusatzmaterialien
Kategorien
Verfügbar in ZB MED Köln/Königswinter
Zs.A 2882: Hefte anzeigen | Standort: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular Jg. 1995 - 2021: Lesesall (2.OG) ab Jg. 2022: Lesesaal (EG) |
Über subito bestellen
Dieser Service ist kostenpflichtig (siehe Lieferbedingungen von subito). Bestellungen, die einen Artikel nebst Supplementary Material umfassen, werden grundsätzlich wie mehrfache Bestellungen bearbeitet. Gebühren fallen in diesen Fällen für jede einzelne Bestellung an.