Artikel ; Online: Rapidly adaptable automated interpretation of point-of-care COVID-19 diagnostics.
Communications medicine
2023 Band 3, Heft 1, Seite(n) 91
Abstract: Background: Point-of-care diagnostic devices, such as lateral-flow assays, are becoming widely used by the public. However, efforts to ensure correct assay operation and result interpretation rely on hardware that cannot be easily scaled or image ... ...
Abstract | Background: Point-of-care diagnostic devices, such as lateral-flow assays, are becoming widely used by the public. However, efforts to ensure correct assay operation and result interpretation rely on hardware that cannot be easily scaled or image processing approaches requiring large training datasets, necessitating large numbers of tests and expert labeling with validated specimens for every new test kit format. Methods: We developed a software architecture called AutoAdapt POC that integrates automated membrane extraction, self-supervised learning, and few-shot learning to automate the interpretation of POC diagnostic tests using smartphone cameras in a scalable manner. A base model pre-trained on a single LFA kit is adapted to five different COVID-19 tests (three antigen, two antibody) using just 20 labeled images. Results: Here we show AutoAdapt POC to yield 99% to 100% accuracy over 726 tests (350 positive, 376 negative). In a COVID-19 drive-through study with 74 untrained users self-testing, 98% found image collection easy, and the rapidly adapted models achieved classification accuracies of 100% on both COVID-19 antigen and antibody test kits. Compared with traditional visual interpretation on 105 test kit results, the algorithm correctly identified 100% of images; without a false negative as interpreted by experts. Finally, compared to a traditional convolutional neural network trained on an HIV test kit, the algorithm showed high accuracy while requiring only 1/50th of the training images. Conclusions: The study demonstrates how rapid domain adaptation in machine learning can provide quality assurance, linkage to care, and public health tracking for untrained users across diverse POC diagnostic tests. |
---|---|
Sprache | Englisch |
Erscheinungsdatum | 2023-06-23 |
Erscheinungsland | England |
Dokumenttyp | Journal Article |
ISSN | 2730-664X |
ISSN (online) | 2730-664X |
DOI | 10.1038/s43856-023-00312-x |
Datenquelle | MEDical Literature Analysis and Retrieval System OnLINE |
Zusatzmaterialien
Kategorien
Über subito bestellen
Dieser Service ist kostenpflichtig (siehe Lieferbedingungen von subito). Bestellungen, die einen Artikel nebst Supplementary Material umfassen, werden grundsätzlich wie mehrfache Bestellungen bearbeitet. Gebühren fallen in diesen Fällen für jede einzelne Bestellung an.
Fernleihe an ZB MED
Sie können sich den gewünschten Titel als lokale Nutzerin oder lokaler Nutzer von ZB MED direkt an den Standort Köln schicken lassen.