Artikel: Ion chromatographic determination of sulfide and cyanide in real matrices by using pulsed amperometric detection on a silver electrode.
2004 Band 1023, Heft 1, Seite(n) 105–112
Abstract: The determination of free sulfide and cyanide by pulsed amperometric detection (PAD) at a silver-working electrode was improved through a deep de-oxygenation (at least 10 min) of both standard and real solutions containing the two analytes and adopting a ...
Abstract | The determination of free sulfide and cyanide by pulsed amperometric detection (PAD) at a silver-working electrode was improved through a deep de-oxygenation (at least 10 min) of both standard and real solutions containing the two analytes and adopting a two-potential waveform able to eliminate Ag working electrode fouling. The waveform stepped around the oxidation of Ag in the presence of 0.1-0.4 M hydroxyl ion, from -0.1 to 0.1 V versus saturated calomel electrode (SCE). The eluent composition (0.4 M NaOH plus 7.5 mM oxalate solution) allowed a very good column efficiency and selectivity. The presence of a polysulfide species was hypothesized in sulfide solutions that had not been de-oxygenated and aged. The polysulfide eluted just before sulfide and was confirmed by a chemical test with SO3(2-) producing the elimination of the polysulfide peak. Detection limits, according to the Hubaux-Vos method, were 1.0 and 2.0 microg/l for S2- and CN , respectively. We demonstrated good performance of the optimized method by repeatedly injecting standard solutions and by analyzing different real matrices. The method exhibited very good accuracy and repeatability (10 microg/l and a 500 microl injection loop, had a repeatability better than 3% for sulfide and 100 microg/l had a repeatability better than 1% for cyanide). The two-potential waveform ensured long-term stability of the electrode surface that required no manual polishing procedure for at least 1 month (20 analysis per day). |
---|---|
Mesh-Begriff(e) | Chromatography, Liquid/methods ; Cyanides/analysis ; Electrochemistry/methods ; Electrodes ; Silver ; Sulfides/analysis |
Chemische Substanzen | Cyanides ; Sulfides ; Silver (3M4G523W1G) |
Sprache | Englisch |
Erscheinungsdatum | 2004-01-09 |
Erscheinungsland | Netherlands |
Dokumenttyp | Journal Article ; Research Support, Non-U.S. Gov't |
ZDB-ID | 1171488-8 |
ISSN | 1873-3778 ; 0021-9673 |
ISSN (online) | 1873-3778 |
ISSN | 0021-9673 |
DOI | 10.1016/j.chroma.2003.10.001 |
Datenquelle | MEDical Literature Analysis and Retrieval System OnLINE |
Volltext online
Zusatzmaterialien
Kategorien
Verfügbar in ZB MED Köln/Königswinter
Zs.A 813: Hefte anzeigen | Standort: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular Jg. 1995 - 2021: Lesesall (1.OG) ab Jg. 2022: Lesesaal (EG) |
Über subito bestellen
Dieser Service ist kostenpflichtig (siehe Lieferbedingungen von subito). Bestellungen, die einen Artikel nebst Supplementary Material umfassen, werden grundsätzlich wie mehrfache Bestellungen bearbeitet. Gebühren fallen in diesen Fällen für jede einzelne Bestellung an.