LIVIVO - Das Suchportal für Lebenswissenschaften

switch to English language
Erweiterte Suche

Suchergebnis

Treffer 1 - 1 von insgesamt 1

Suchoptionen

Artikel ; Online: A first-in-human study of BLZ-100 (tozuleristide) demonstrates tolerability and safety in skin cancer patients

Miko Yamada / Dennis M. Miller / Melinda Lowe / Casey Rowe / Dominic Wood / H. Peter Soyer / Kelly Byrnes-Blake / Julia Parrish-Novak / Laura Ishak / James M. Olson / Gordon Brandt / Paul Griffin / Lynda Spelman / Tarl W. Prow

Contemporary Clinical Trials Communications, Vol 23, Iss , Pp 100830- (2021)

2021  

Abstract: BLZ-100 (tozuleristide) is an intraoperative fluorescent imaging agent that selectively detects malignant tissue and can be used in real time to guide tumor resection. The purpose of this study was to assess the safety, tolerability, and pharmacokinetics ...

Abstract BLZ-100 (tozuleristide) is an intraoperative fluorescent imaging agent that selectively detects malignant tissue and can be used in real time to guide tumor resection. The purpose of this study was to assess the safety, tolerability, and pharmacokinetics of BLZ-100 and to explore the pharmacodynamics of fluorescence imaging of skin tumors. In this first-in-human study, BLZ-100 was administered intravenously to 21 adult patients 2 days before excising known or suspected skin cancers. Doses were 1, 3, 6, 12, and 18 mg, with 3–6 patients/cohort. Fluorescence imaging was conducted before and up to 48 h after dosing. BLZ-100 was well tolerated. There were no serious adverse events, deaths, or discontinuations due to adverse events, and no maximum tolerated dose (MTD) was identified. Headache (n = 2) and nausea (n = 2) were the only BLZ-100 treatment-related adverse events reported for >1 patient. Median time to maximal serum concentration was <0.5 h. Exposure based on maximal serum concentrations increased in a greater than dose-proportional manner. For intermediate dose-levels (3–12 mg), 4 of 5 basal cell carcinomas and 4 of 4 melanomas were considered positive for BLZ-100 fluorescence. BLZ-100 was well tolerated at all dose levels tested and these results support further clinical testing of this imaging agent in surgical oncology settings. Clinicaltrials.gov: NCT02097875.
Schlagwörter Skin neoplasms ; Fluorescent dyes ; Cystine-knot miniproteins ; Medicine (General) ; R5-920
Thema/Rubrik (Code) 616 ; 610
Sprache Englisch
Erscheinungsdatum 2021-09-01T00:00:00Z
Verlag Elsevier
Dokumenttyp Artikel ; Online
Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

Zusatzmaterialien

Kategorien

Zum Seitenanfang